Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement

Author:

Van Mieghem Nicolas M.1,Schipper Marguerite E.I.1,Ladich Elena1,Faqiri Elham1,van der Boon Robert1,Randjgari Abas1,Schultz Carl1,Moelker Adriaan1,van Geuns Robert-Jan1,Otsuka Fumiyuki1,Serruys Patrick W.1,Virmani Renu1,de Jaegere Peter P.1

Affiliation:

1. From the Department of Interventional Cardiology, Thoraxcenter, Erasmus Medical Center, Rotterdam, The Netherlands (N.M.v.M., E.F., R.v.d.B., C.S., R.-J.v.G., P.W.S., P.P.d.J.); Department of Pathology, Erasmus Medical Center, Rotterdam, The Netherlands (M.E.I.S., A.R.); Cardiovascular Pathology Institute, Inc., Gaithersburg, MD (E.L., F.O., R.V.); and Department of Radiology, Erasmus Medical Center, Rotterdam, The Netherlands (A.M.).

Abstract

Background— Recent transcatheter aortic valve replacement studies have raised concerns about adverse cerebrovascular events. The etiopathology of the embolized material is currently unknown. Methods and Results— A total of 40 patients underwent transcatheter aortic valve replacement with the use of a dual filter–based embolic protection device (Montage Dual Filter System, Claret Medical, Inc). Macroscopic material liberated during the transcatheter aortic valve replacement procedure was captured in the device filter baskets in 30 (75%) patients and sent for histopathologic analysis. The captured material varied in size from 0.15 to 4.0 mm. Amorphous calcified material (size, 0.55–1.8 mm) was identified in 5 patients (17%). In 8 patients (27%), the captured material (size, 0.25–4.0 mm) contained valve tissue composed of loose connective tissue (collagen and elastic fibers) with focal areas of myxoid stroma, with or without coverage by endothelial cells and intermixed with fibrin. In another 13 (43%) patients, collagenous tissue, which may represent elements of vessel wall and valvelike structures, was identified. In 9 patients (30%), thrombotic material was intermixed with neutrophils (size, 0.15–2.0 mm). Overall, thrombotic material was found in 52% of patients, and tissue fragments compatible with aortic valve leaflet or aortic wall origin were found in 52% (21/40) of patients. Conclusions— Embolic debris traveling to the brain was captured in 75% of transcatheter aortic valve replacement procedures where a filter-based embolic protection device was used. The debris consisted of fibrin, or amorphous calcium and connective tissue derived most likely from either the native aortic valve leaflets or aortic wall.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3