The Myoblast Autologous Grafting in Ischemic Cardiomyopathy (MAGIC) Trial

Author:

Menasché Philippe1,Alfieri Ottavio1,Janssens Stefan1,McKenna William1,Reichenspurner Hermann1,Trinquart Ludovic1,Vilquin Jean-Thomas1,Marolleau Jean-Pierre1,Seymour Barbara1,Larghero Jérôme1,Lake Stephen1,Chatellier Gilles1,Solomon Scott1,Desnos Michel1,Hagège Albert A.1

Affiliation:

1. From Assistance Publique-Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Département de Chirurgie Cardio-vasculaire; Université Paris Descartes, Faculté de Médecine; INSERM U633, Laboratoire de Recherches Biochirurgicales, Paris, France (P.M.); Ospedale San Raffaele, Dipartimento Cardiochirugia, Milano, Italy (O.A.); UZ Gasthuisberg, Cardiology Department, Leuven, Belgium (S.J.); The Heart Hospital, London, UK (W.M.); Universitätsklinikum Hamburg-Eppendorf, Klinik und Poliklinik für...

Abstract

Background— Phase I clinical studies have demonstrated the feasibility of implanting autologous skeletal myoblasts in postinfarction scars. However, they have failed to determine whether this procedure was functionally effective and arrhythmogenic. Methods and Results— This multicenter, randomized, placebo-controlled, double-blind study included patients with left ventricular (LV) dysfunction (ejection fraction ≤35%), myocardial infarction, and indication for coronary surgery. Each patient received either cells grown from a skeletal muscle biopsy or a placebo solution injected in and around the scar. All patients received an implantable cardioverter-defibrillator. The primary efficacy end points were the 6-month changes in global and regional LV function assessed by echocardiography. The safety end points comprised a composite index of major cardiac adverse events and ventricular arrhythmias. Ninety-seven patients received myoblasts (400 or 800 million; n=33 and n=34, respectively) or the placebo (n=30). Myoblast transfer did not improve regional or global LV function beyond that seen in control patients. The absolute change in ejection fraction (median [interquartile range]) between 6 months and baseline was 4.4% (0.2; 7.3), 3.4% (−0.3; 12.4), and 5.2% (−4.4; 11.0) in the placebo, low-dose, and high-dose groups, respectively ( P =0.95). However, the high-dose cell group demonstrated a significant decrease in LV volumes compared with the placebo group. Despite a higher number of arrhythmic events in the myoblast-treated patients, the 6-month rates of major cardiac adverse events and of ventricular arrhythmias did not differ significantly between the pooled treatment and placebo groups. Conclusions— Myoblast injections combined with coronary surgery in patients with depressed LV function failed to improve echocardiographic heart function. The increased number of early postoperative arrhythmic events after myoblast transplantation, as well as the capability of high-dose injections to revert LV remodeling, warrants further investigation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3