Correlation of Intravascular Ultrasound Findings With Histopathological Analysis of Thrombus Aspirates in Patients With Very Late Drug-Eluting Stent Thrombosis

Author:

Cook Stéphane1,Ladich Elena1,Nakazawa Gaku1,Eshtehardi Parham1,Neidhart Michel1,Vogel Rolf1,Togni Mario1,Wenaweser Peter1,Billinger Michael1,Seiler Christian1,Gay Steffen1,Meier Bernhard1,Pichler Werner J.1,Jüni Peter1,Virmani Renu1,Windecker Stephan1

Affiliation:

1. From the Department of Cardiology, Bern University Hospital, Bern, Switzerland (S.C., P.E., R.V., M.T., P.W., M.B., C.S., B.M., S.W.); CVPath Institute Inc, Gaithersburg, Md (E.L., G.N., R.V.); World Health Organization Collaborating Center for Molecular Biology and Novel Therapeutic Strategies for Rheumatic Diseases, University Hospital Zürich, Zürich, Switzerland (M.N., S.G.); Institute of Social and Preventive Medicine, University of Bern, Bern, Switzerland (P.J.); and Division of Allergology,...

Abstract

Background— Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. Methods and Results— The study population consisted of 54 patients (28 patients with very late DES ST and 26 controls). Of 28 patients with very late DES ST, 10 patients (1020±283 days after implantation) with 11 ST segments (5 sirolimus-eluting stents, 5 paclitaxel-eluting stents, 1 zotarolimus-eluting stent) underwent both thrombus aspiration and intravascular ultrasound investigation. ISA was present in 73% of cases with an ISA cross-sectional area of 6.2±2.4 mm 2 and evidence of vessel remodeling (index, 1.6±0.3). Histopathological analysis showed pieces of fresh thrombus with inflammatory cell infiltrates (DES, 263±149 white blood cells per high-power field) and eosinophils (DES, 20±24 eosinophils per high-power field; sirolimus-eluting stents, 34±28; paclitaxel-eluting stents, 6±6; P for sirolimus-eluting stents versus paclitaxel-eluting stents=0.09). The mean number of eosinophils per high-power field was higher in specimens from very late DES ST (20±24) than in those from spontaneous acute myocardial infarction (7±10), early bare-metal stent ST (1±1), early DES ST (1±2), and late bare-metal stent ST (2±3; P from ANOVA=0.038). Eosinophil count correlated with ISA cross-sectional area, with an average increase of 5.4 eosinophils per high-power field per 1-mm 2 increase in ISA cross-sectional area. Conclusions— Very late DES thrombosis is associated with histopathological signs of inflammation and intravascular ultrasound evidence of vessel remodeling. Compared with other causes of myocardial infarction, eosinophilic infiltrates are more common in thrombi harvested from very late DES thrombosis, particularly in sirolimus-eluting stents, and correlate with the extent of stent malapposition.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3