Diagnostic Ultrasound Combined With Glycoprotein IIb/IIIa–Targeted Microbubbles Improves Microvascular Recovery After Acute Coronary Thrombotic Occlusions

Author:

Xie Feng1,Lof John1,Matsunaga Terry1,Zutshi Reena1,Porter Thomas R.1

Affiliation:

1. From the Department of Internal Medicine, Section of Cardiology, University of Nebraska Medical Center, Omaha (F.X., J.L., T.R.P.); Department of Radiology Research, University of Arizona, Tucson (T.M.); and ImaRx Therapeutics, Inc, Tucson, Ariz (R.Z.).

Abstract

Background— The high mechanical index (MI) impulses from a diagnostic ultrasound transducer may be a method of recanalizing acutely thrombosed vessels if the impulses are applied only when microbubbles are channeling through the thrombus. Methods and Results— In 45 pigs with acute left anterior descending thrombotic occlusions, a low-MI pulse sequence scheme (contrast pulse sequencing) was used to image the myocardium and guide the delivery of high-MI (1.9 MI) impulses during infusion of either intravenous platelet-targeted microbubbles or nontargeted microbubbles. A third group received no diagnostic ultrasound and microbubbles. All groups received half-dose recombinant prourokinase, heparin, and aspirin. Contrast pulse sequencing examined replenishment of contrast within the central portion of the risk area and guided the application of high-MI impulses. Angiographic recanalization rates, resolution of ST-segment elevation on ECG, and wall thickening were analyzed. Pigs receiving platelet-targeted microbubbles had more rapid replenishment of the central portion of the risk area (80% versus 40% for nontargeted microbubbles; P =0.03) and higher epicardial recanalization rates (53% versus 7% for prourokinase alone; P =0.01). Replenishment of contrast within the risk area (whether with platelet-targeted microbubbles or nontargeted microbubbles) was associated with both higher recanalization rates and even higher rates of ST-segment resolution (82% versus 21% for prourokinase alone; P =0.006). ST-segment resolution occurred in 6 pigs (40%) treated with microbubbles who did not have epicardial recanalization, of which 5 had recovery of wall thickening. Conclusions— Intravenous platelet-targeted microbubbles combined with brief high-MI diagnostic ultrasound impulses guided by contrast pulse sequencing improve both epicardial recanalization rates and microvascular recovery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 106 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3