Effects of Levosimendan on Left Ventricular Relaxation and Early Filling at Maintained Preload and Afterload Conditions After Aortic Valve Replacement for Aortic Stenosis

Author:

Jörgensen Kirsten1,Bech-Hanssen Odd1,Houltz Erik1,Ricksten Sven-Erik1

Affiliation:

1. From the Department of Cardiothoracic Anesthesia and Intensive Care (K.J., E.H., S.-E.R.) and Department of Clinical Physiology (O.B.-H.), Sahlgrenska University Hospital, Gothenburg, Sweden, and Department of Anaesthesia, Pain and Hyperbaric Medicine, Royal Adelaide Hospital, Adelaide, Australia (K.J.).

Abstract

Background— We determined the effects of levosimendan, a calcium sensitizer, on left ventricular (LV) diastolic function in patients with LV hypertrophy. Methods and Results— In this prospective, randomized, blinded study, 23 patients received either levosimendan (0.1 and 0.2 μg · kg −1 · min −1 ; n=12) or placebo (n=11) after aortic valve replacement for aortic stenosis. The effects on LV performance, dimensions, filling patterns, and isovolumic relaxation time, as well as systemic hemodynamics, were assessed by pulmonary artery thermodilution catheterization and transesophageal 2-dimensional Doppler echocardiography. To circumvent the confounding effects of the levosimendan-induced hemodynamic changes on Doppler echocardiographic indexes of LV early relaxation, heart rate and mean arterial and central venous pressures were kept constant during levosimendan/placebo infusion by atrial pacing, vasopressor, and colloid infusions. In the levosimendan group, dose-dependent increases in cardiac output (28%; P <0.001) and stroke volume (26%; P <0.001) and a decrease in systemic vascular resistance (−22%; P <0.001) were observed. There was a trend for an increase in LV ejection fraction (12%; P =0.058) with levosimendan. There were no significant differences in systolic, diastolic arterial, or LV filling pressures or LV end-diastolic area between the 2 groups. Isovolumic relaxation time decreased (−23%; P <0.001), as did the deceleration slope of early diastolic filling (−45%; P <0.01), whereas peak early diastolic filling velocity (16%, P <0.01) and peak late diastolic filling velocity (15%; P <0.001) increased after levosimendan compared with placebo. Conclusion— Levosimendan, in addition to its inotropic effects, exerts a direct positive lusitropic effect in patients with LV hypertrophy as it shortens isovolumic relaxation time and improves LV filling.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 72 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3