Visceral Arterial Compromise During Intra-Aortic Balloon Counterpulsation Therapy

Author:

Rastan Ardawan Julian1,Tillmann Eugen1,Subramanian Sreekumar1,Lehmkuhl Lukas1,Funkat Anne Kathrin1,Leontyev Sergej1,Doenst Torsten1,Walther Thomas1,Gutberlet Matthias1,Mohr Friedrich Wilhelm1

Affiliation:

1. From the Department of Cardiac Surgery (A.J.R., E.T., S.S., A.K.F., S.L., T.D., T.W., F.W.M.) and the Department of Radiology (L.L., M.G.), Heart Center, University of Leipzig, Germany.

Abstract

Background— Intraaortic balloon pump (IABP) therapy is a widely used method of circulatory support. Based on frequent findings of balloon malposition with visceral arterial compromise on computerized tomographic (CT) imaging studies, we conducted a systematic review of cardiac surgical IABP patients with available CT scans to determine reasons, incidence, and clinical relevance of malposition. Methods and Results— From January 2007 to March 2009, a total of 621 of 7756 cardiac surgical patients (8.0%) received perioperative IABP support, of whom 63 (10.1%) received a thoracoabdominal CT scan during IABP support. Proximal and distal balloon positions were analyzed. The anatomic distance from the left subclavian artery to celiac trunk and aortic transverse diameter were measured in all patients and compared with implanted balloon dimensions. Mean age was 67.1±11.9 years; 33.3% were female, and height was 169±9 cm. Based on radiography, proximal balloon position was correct in 96.8% but only appropriate in 38.1% based on CT. In 61 of 63 patients, compromise of at least 1 visceral artery was found: celiac trunk, 96.8%; superior mesenteric artery, 87.3%; and renal arteries, 66.7%. Left subclavian artery to celiac trunk distance was 241±23 mm, and balloon length was 248±17 mm and corresponded to an anatomic to balloon length mismatch in 68.2%. Spinal deformations were found in 42.9%. Laparotomy for mesenteric ischemia was required in 23.8%. Hospital mortality rate was 60.3%. Conclusions— IABP malposition was commonly identified by CT. Reasons included incorrect proximal balloon position as well as an anatomic-to-balloon length mismatch. Thus, shorter than recommended balloon sizes and better positioning strategies had to be considered.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 75 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3