Cardiac Magnetic Resonance With T2-Weighted Imaging Improves Detection of Patients With Acute Coronary Syndrome in the Emergency Department

Author:

Cury Ricardo C.1,Shash Khalid1,Nagurney John T.1,Rosito Guido1,Shapiro Michael D.1,Nomura Cesar H.1,Abbara Suhny1,Bamberg Fabian1,Ferencik Maros1,Schmidt Ehud J.1,Brown David F.1,Hoffmann Udo1,Brady Thomas J.1

Affiliation:

1. From the Cardiac MR-PET-CT Program (R.C.C., K.S., G.R., M.D.S., C.H.N., S.A., F.B., M.F., U.H., T.J.B.), Department of Radiology (R.C.C., K.S., G.R., M.D.S., C.H.N., S.A., F.B., U.H., T.J.B.), Department of Emergency Medicine (J.T.N., D.F.B.), and Cardiology Division (M.F., E.J.S.), Massachusetts General Hospital and Harvard Medical School, Boston.

Abstract

Background— Cardiac magnetic resonance (CMR) imaging permits early triage of patients presenting to the emergency department with acute chest pain but has been limited by the inability to differentiate new from old myocardial infarction. Our objective was to evaluate a CMR protocol that includes T2-weighted imaging and assessment of left ventricular wall thickness in detecting patients with acute coronary syndrome in the emergency department. Methods and Results— In this prospective cohort observational study, we enrolled patients presenting to the emergency department with acute chest pain, negative cardiac biomarkers, and no ECG changes indicative of acute ischemia. The CMR protocol consisted of T2-weighted imaging, first-pass perfusion, cine function, delayed-enhancement magnetic resonance imaging, and assessment of left ventricular wall thickness. The clinical outcome (acute coronary syndrome) was defined by review of clinical charts by a consensus panel that used American Heart Association/American College of Cardiology guidelines. Among 62 patients, 13 developed acute coronary syndrome during the index hospitalization. The mean CMR time was 32±8 minutes. The new CMR protocol (with the addition of T2-weighted and left ventricular wall thickness) increased the specificity, positive predictive value, and overall accuracy from 84% to 96%, 55% to 85%, and 84% to 93%, respectively, compared with the conventional CMR protocol (cine, perfusion, and delayed-enhancement magnetic resonance imaging). Moreover, in a logistic regression analysis that contained information on clinical risk assessment (c-statistic=0.695) and traditional cardiac risk factors (c-statistic=0.771), the new CMR protocol significantly improved the c-statistic to 0.958 ( P <0.0001). Conclusions— The present study indicates that a new CMR protocol improves the detection of patients with acute coronary syndrome in the emergency department and adds significant value over clinical assessment and traditional cardiac risk factors.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3