Low Operative Mortality With Implantation of a Continuous-Flow Left Ventricular Assist Device and Impact of Concurrent Cardiac Procedures

Author:

Pal Jay D.1,Klodell Charles T.1,John Ranjit1,Pagani Francis D.1,Rogers Joseph G.1,Farrar David J.1,Milano Carmelo A.1

Affiliation:

1. From the Department of Surgery (J.D.P., C.A.M.) and the Department of Medicine (J.G.R.), Duke University Medical Center, Durham, NC; the Department of Surgery (C.T.K.), University of Florida, Gainesville, FL; the Department of Surgery (R.J.) University of Minnesota, Minneapolis, MN; the Department of Surgery (F.D.P.), University of Michigan, Ann Arbor, MI; and Thoratec Corporation (D.J.F.), Pleasanton, CA.

Abstract

Background— The objective of this study was to determine the impact of concurrent cardiac procedures (CCP) on patient outcomes after HeartMate II (HMII) left ventricular assist device implantation. Methods and Results— Two hundred eighty-one patients underwent implantation of a HMII as a bridge to transplantation from March 2005 to March 2007. One hundred seventy patients had an HMII implanted only, and 81 patients underwent concurrent cardiac procedures in conjunction with HMII implantation (HMII+CCP). Of these, 47 patients had concurrent valvular procedures, 15 patients had simultaneous closure of patent foramen ovale, and 19 patients had other various cardiac procedures. Patients requiring right ventricular assist device support or noncardiac procedures were excluded. Preoperative characteristics were similar for patients with and without concurrent cardiac procedures. Overall 30-day mortality was 5.8% for the HMII group and 11.3% for the HMII+CCP group. Subgroup analysis demonstrated that simultaneous patent foramen ovale closure was not associated with an increased 30-day mortality rate, but concurrent valvular procedures increased the risk to 8.5%. Patients who underwent an aortic valve procedure had a 30-day mortality rate of 25%, higher than for isolated concurrent mitral (0%) or tricuspid repair (3.3%). Survival at 180 days was 87% for HMII alone and 80% for HMII+CCP. The hazard ratio for concurrent cardiac procedures adjusted for baseline parameters was 1.82 (95% CI, 1.07 to 3.10, P =0.026). Conclusions— There is a low 5.8% operative mortality rate for patients requiring uncomplicated HMII implantation, with no apparent increased risk for concurrent patent foramen ovale closure or mitral or tricuspid repair. However, concurrent aortic valve and other cardiac procedures are associated with significantly decreased perioperative and long-term survival.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 96 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3