Exposure to Low-Dose Ionizing Radiation From Cardiac Procedures and Malignancy Risk in Adults With Congenital Heart Disease

Author:

Cohen Sarah1,Liu Aihua1,Gurvitz Michelle2,Guo Liming1,Therrien Judith1,Laprise Claudie3,Kaufman Jay S.4,Abrahamowicz Michal4,Marelli Ariane J.1

Affiliation:

1. McGill Adult Unit for Congenital Heart Disease Excellence, Montreal, Quebec, Canada (S.C., A.L., L.G., J.T., A.J.M.)

2. Department of Cardiology, Children’s Hospital Boston, Harvard Medical School, MA (M.G.)

3. Gerald Bronfman Department of Oncology, Division of Cancer Epidemiology (C.L.), Division of Oral Health and Society, Faculty of Dentistry (C.L.)

4. Department of Epidemiology, Biostatistics, and Occupational Health (J.S.K., M.A.), McGill University, Montreal, Quebec, Canada

Abstract

Background: Adults with congenital heart disease (CHD) are exposed to increasing amounts of low-dose ionizing radiation (LDIR) from cardiac procedures. Cancer prevalence in this population is higher than in the general population. This study estimates the association between LDIR exposure from cardiac procedures and incident cancer in adult patients with CHD. Methods: The study population derived from the Quebec Congenital Heart Disease Database. We measured cumulative numbers of LDIR-related cardiac procedures for each patient until 1 year before the time of cancer diagnosis or administrative censoring. To assess the association between LDIR exposure and cancer risk, we conducted a nested case-control study and matched cancer cases with controls on sex, CHD severity, birth year, and age. Results: The study included 24 833 adult patients with CHD aged 18 to 64 years from 1995 to 2009. In >250 791 person-years of follow-up, 602 cancer cases were observed (median age, 55.4 years). The cumulative incidence of cancer estimated up to 64 years of age was 15.3% (95% confidence interval [CI], 14.2–16.5). Cases had more LDIR-related cardiac procedures than controls (1410 versus 921 per 1000 adult patients with CHD, P <0.0001). Cumulative LDIR exposure was independently associated with cancer (odds ratio [OR], 1.08 per procedure; 95% CI, 1.04–1.13). Similar results were obtained by using dose estimates for LDIR exposure (OR, 1.10 per 10 mSv; 95% CI, 1.05–1.15) with a possible dose-related response. The effect measure was in the same direction, and the association was persistent for exposure from ≥6 procedures in all sensitivity analyses: after excluding most smoking-related cancer cases (OR, 1.10 per procedure; 95% CI, 1.05–1.16 and OR when exposure from ≥6 procedures, 3.08; 95% CI, 1.77–5.37), and after applying a 3-year lag period (OR, 1.09 per procedure; 95% CI, 1.03–1.14 and OR when exposure from ≥6 procedures: 2.58; 95% CI, 1.43–4.69). Conclusions: To our knowledge, this is the first large population-based study to analyze and document the association between LDIR-related cardiac procedures and incident cancer in the population of adults with CHD. Confirmations of these findings by prospective studies are needed to reinforce policy recommendations for radiation surveillance in patients with CHD where no regulation currently exists. Physicians ordering and performing cardiac imaging should ensure that exposure is as low as reasonably achievable without sacrificing quality of care.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 93 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370