Comparison of Cardiovascular Magnetic Resonance and Single-Photon Emission Computed Tomography in Women With Suspected Coronary Artery Disease From the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) Trial

Author:

Greenwood John P.1,Motwani Manish1,Maredia Neil1,Brown Julia M.1,Everett Colin C.1,Nixon Jane1,Bijsterveld Petra1,Dickinson Catherine J.1,Ball Stephen G.1,Plein Sven1

Affiliation:

1. From the Multidisciplinary Cardiovascular Research Centre and Division of Cardiovascular and Diabetes Research, Leeds Institute of Genetics, Health & Therapeutics (J.P.G., M.M., N.M., P.B., S.G.B., S.P.) and Clinical Trials Research Unit (J.M.B., C.C.E., J.N.), University of Leeds, Leeds, UK; and Department of Nuclear Cardiology, Leeds General Infirmary, Leeds, UK (C.J.D.).

Abstract

Background— Coronary artery disease is the leading cause of death in women, and underdiagnosis contributes to the high mortality. This study compared the sex-specific diagnostic performance of cardiovascular magnetic resonance (CMR) and single-photon emission computed tomography (SPECT). Methods and Results— A total of 235 women and 393 men with suspected angina underwent CMR, SPECT, and x-ray angiography as part of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) study. CMR comprised adenosine stress/rest perfusion, cine imaging, late gadolinium enhancement, and magnetic resonance coronary angiography. Gated adenosine stress/rest SPECT was performed with 99m Tc-tetrofosmin. For CMR, the sensitivity in women and men was similar (88.7% versus 85.6%; P =0.57), as was the specificity (83.5% versus 82.8%; P =0.86). For SPECT, the sensitivity was significantly worse in women than in men (50.9% versus 70.8%; P =0.007), but the specificities were similar (84.1% versus 81.3%; P =0.48). The sensitivity in both the female and male groups was significantly higher with CMR than SPECT ( P <0.0001 for both), but the specificity was similar ( P =0.77 and P =1.00, respectively). For perfusion-only components, CMR outperformed SPECT in women (area under the curve, 0.90 versus 0.67; P <0.0001) and in men (area under the curve, 0.89 versus 0.74; P <0.0001). Diagnostic accuracy was similar in both sexes with perfusion CMR ( P =1.00) but was significantly worse in women with SPECT ( P <0.0001). Conclusions— In both sexes, CMR has greater sensitivity than SPECT. Unlike SPECT, there are no significant sex differences in the diagnostic performance of CMR. These findings, plus an absence of ionizing radiation exposure, mean that CMR should be more widely adopted in women with suspected coronary artery disease. Clinical Trial Registration— URL: http://www.controlled-trials.com . Unique identifier: ISRCTN77246133.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 142 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3