The Complete Supraannular Concept

Author:

Ruzicka Daniel J.1,Hettich Ina1,Hutter Andrea1,Bleiziffer Sabine1,Badiu Catalin C.1,Bauernschmitt Robert1,Lange Ruediger1,Eichinger Walter B.1

Affiliation:

1. From the Department for Cardiovascular Surgery, German Heart Center, Munich, Germany.

Abstract

Background— Complete supraannular placement of an aortic bioprosthesis is one approach to optimize the hemodynamic result of an aortic valve replacement. It is achieved with the combination of a special valve design and the supraannular sewing technique with noneverted mattress sutures. We evaluated 5 bioprostheses designed for complete supraannular placement to assess potential hemodynamic differences caused by factors (eg, valve material) other than implantation position. Methods and Results— In 336 patients (mean age, 72.0±7.1 years; 143 women), hemodynamics including mean pressure gradients, effective orifice areas, and indices and incidence of patient-prosthesis mismatch were evaluated 6 months after surgery. Annulus diameter was measured during surgery. Patients received the Carpentier Edwards Perimount Magna (Magna, n=169), the Medtronic Mosaic (Mosaic, n=46), the Mosaic Ultra (Ultra, n=17), the SJM Epic Supra (Epic, n=46), and the Sorin Soprano (Soprano, n=58). For small annulus sizes (<23 mm), the mean pressure gradients of the Magna (11.82±4.8 mm Hg) were significantly lower than the Mosaic (16.04±6.1 mm Hg) and the Ultra (22.0±4.1 mm Hg), and the Soprano (13.3±5.2 mm Hg) was hemodynamically superior to the Ultra. For medium (23 to 24 mm) and large (>24 mm) annulus sizes, the mean pressure gradients of the Magna were lower than the Epic (10.0±3.5 mm Hg versus 14.9±6.4 mm Hg; 9.9±4.0 mm Hg versus 18.6±12.7 mm Hg). Furthermore, in patients with large annulus size, the mean pressure gradients of the Soprano (11.4±3.8 mm Hg) were lower compared with the Epic (18.5±12.7 mm Hg). Severe patient-prosthesis mismatch was observed more frequently in patients with the Mosaic (12/46; 26.1%) and the Ultra (3/17; 17.6%) prostheses. Conclusions— Complete supraannular placement cannot prevent high pressure gradients or patient-prosthesis mismatch thoroughly, but the choice of a bovine prosthesis can optimize hemodynamic performance.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3