Randomized Comparison of Stentless Versus Stented Valves for Aortic Stenosis

Author:

Perez de Arenaza Diego1,Lees Belinda1,Flather Marcus1,Nugara Fiona1,Husebye Trygve1,Jasinski Marek1,Cisowski Marek1,Khan Mohammed1,Henein Michael1,Gaer Jullien1,Guvendik Levant1,Bochenek Andrzej1,Wos Stanislaw1,Lie Mons1,Van Nooten Guido1,Pennell Dudley1,Pepper John1

Affiliation:

1. From the Royal Brompton and Harefield NHS Trust, London, UK (D.P.d.A., B.L., M.F., F.N., M.K., M.H., J.G., D.P., J.P.); Hospital Italiano, Buenos Aires, Argentina (D.P.d.A.); National Heart and Lung Institute, Imperial College, London, UK (B.L., M.F., M.K., M.H., D.P., J.P.); Ullevaal Sykehus, Oslo, Norway (T.H., M.L.); Medical University of Silesia, Katowice, Poland (M.J., M.C., A.B., S.W.); Castle Hill Hospital, Hull, UK (L.G.); and UZ Gent, Gent, Belgium (G.V.N.).

Abstract

Background— Aortic valve replacement (AVR) is the established treatment for severe aortic stenosis. In response to the long-term results of aortic homografts, stentless porcine valves were introduced as an alternative low-resistance valve. We conducted a randomized trial comparing a stentless with a stented porcine valve in adults with severe aortic stenosis. Methods and Results— The primary outcome was change in left ventricular mass index (LVMI) measured by transthoracic echocardiography and, in a subset, by cardiovascular MR. Measurements were taken before valve replacement and at 6 and 12 months. Patients undergoing AVR with an aortic annulus ≤25 mm in diameter were randomly allocated to a stentless (n=93) or a stented supra-annular (n=97) valve. There were no significant differences in mean LVMI between the stentless versus stented groups at baseline (176±62 and 182±63 g/m 2 , respectively) or at 6 months (142±49 and 131±45 g/m 2 , respectively), although within-group changes from baseline to 6 months were highly significant. Changes in LVMI measured by cardiovascular MR (n=38) were consistent with the echo findings. There was a greater reduction in peak aortic velocity ( P <0.001) and a greater increase in indexed effective orifice area ( P <0.001) in the stentless group than in the stented group. There were no differences in clinical outcomes between the 2 valve groups. Conclusions— Despite significant differences in indexed effective orifice area and peak flow velocity in favor of the stentless valve, there were similar reductions in left ventricular mass at 6 months with both stented and stentless valves, which persisted at 12 months.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 87 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3