Nonuniform epicardial activation and repolarization properties of in vivo canine pulmonary conus.

Author:

Burgess M J1,Steinhaus B M1,Spitzer K W1,Ershler P R1

Affiliation:

1. Nora Eccles Harrison Cardiovascular Research, University of Utah, Salt Lake City 84112.

Abstract

The relation between nonuniform epicardial activation and ventricular repolarization properties was studied in 14 pentobarbital anesthetized dogs and with a computer model. In 11 dogs, isochrone maps of epicardial activation sequence were constructed from electrograms recorded from the pulmonary conus with 64 electrodes on an 8 X 8 grid with 2-mm electrode separation. The heart was paced from multiple sites on the periphery of the array. Uniformity of epicardial activation was estimated from activation times at test sites and their eight neighboring sites. Acceleration shortened and deceleration prolonged refractory periods. The locations of acceleration and deceleration sites of activation differed during drives from various sites, and differences in uniformity of activation during pairs of drives were correlated to differences in refractory periods (r = 0.76, range 0.59-0.93). In three additional experiments, transmural activation sequence maps were constructed from electrograms recorded from needle-mounted electrodes placed upstream and downstream to epicardial activation delays. Activation proceeded from epicardium to endocardium upstream to the delays and from endocardium to epicardium downstream to the delays. A computer simulation of two-dimensional action potential propagation based on the Beeler-Reuter myocardial membrane model provided insights to the mechanism for the results of the animal experiments. The two-dimensional sheet modeled the transmural anisotropic histology of the canine pulmonary conus and corresponded to previous reports and histology of specimens from five experiments. Simulated activation patterns were similar to those found in the experimental animals. In addition, action potentials were electronically prolonged at sites of deceleration and shortened at sites of acceleration, results comparable to the animal experiments. Our findings demonstrate that the location of areas of nonuniform epicardial activation is dependent on drive site and that nonuniform activation electronically modulates repolarization properties. Therefore it seems likely that the site of origin of ectopic ventricular complexes, especially in ischemic myocardium where activation is nonuniform, could be an important determinant of whether ectopic activity initiates sustained tachyarrhythmias.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference41 articles.

1. Effects of activation sequence on ventricular refractory periods of ischemic canine myocardium

2. Steinhaus BM Spitzer KW: Simulation of activation sequence effects in heart tissue. Proc IEEE/Frontiers ofEngineering and Computing in Health Care Conference Columbus Ohio Sept 1983 pp 199-204

3. Action Potential Collision in Heart Tissue-Computer Simulations and Tissue Expenrments

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3