Pericardial influences on right and left ventricular filling dynamics.

Author:

Hoit B D1,Dalton N1,Bhargava V1,Shabetai R1

Affiliation:

1. Department of Medicine, Veterans Administration Medical Center, San Diego, Calif.

Abstract

The influence of the pericardium on right and left ventricular filling was studied using two-dimensional and Doppler echocardiography in 14 open-chest dogs. Doppler echo parameters of filling included early (E) and late (A) velocities and their ratio (E/A) for the mitral and tricuspid valves. Right and left ventricular volumes were calculated from orthogonal two-dimensional echocardiographic images. Data were compared at three levels of left ventricular end-diastolic pressure (6 +/- 2, 13 +/- 3, and 21 +/- 4 mm Hg) at matched heart rates before and after pericardiectomy. The instantaneous diastolic pressure gradient was measured in 12 of the dogs. Pericardiectomy resulted in an increase in early mitral velocity, peak early diastolic pressure gradient, and E/A but not early mitral velocity normalized for end-diastolic volume. In contrast, for the tricuspid valve flow, pericardiectomy did not change E but caused a marked increase in A and a decrease in E/A. Right ventricular end-diastolic volumes at matched left ventricular end-diastolic volumes were similar before and after the pericardium was removed. However, removal of the pericardium caused a significant decrease of the slope for the right (86.0 +/- 27.0 x 10(-4) versus 50.0 +/- 19.5 x 10(-4) mm Hg/ml, p less than 0.01), but not left, ventricular ln end-diastolic pressure-volume relation (21.2 +/- 9.2 x 10(-3) versus 21.4 +/- 5.3 x 10(-3) mm Hg/ml, p = NS), and a decrease of the pressure intercept for the left (3.0 +/- 2.0 versus 1.6 +/- 0.9 mm Hg, p less than 0.05), but not right, ventricular ln end-diastolic pressure-volume relation (2.8 +/- 1.4 versus 1.4 +/- 0.8 mm Hg, p = NS). In conclusion, filling of the two ventricles is affected by the pericardium over a wide range of physiological ventricular volumes and pressures. At matched left ventricular end-diastolic volume, pericardiectomy causes a fundamental alteration in right, but not left, ventricular filling.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 45 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3