Vagal stimulation and prevention of sudden death in conscious dogs with a healed myocardial infarction.

Author:

Vanoli E1,De Ferrari G M1,Stramba-Badiale M1,Hull S S1,Foreman R D1,Schwartz P J1

Affiliation:

1. Department of Physiology and Biophysics, University of Oklahoma, Oklahoma City.

Abstract

The interest for the antifibrillatory effect of vagal stimulation has been largely limited by the fact that this concept seemed restricted to acute experiments in anesthetized animals. To explore the potentially protective role of vagal stimulation in conscious animals we developed a chronically implantable device to be placed around the cervical right vagus. An anterior myocardial infarction was produced in 161 dogs; 1 month later an exercise stress test was performed on the 105 survivors. Toward the end of the test the circumflex coronary artery was occluded for 2 minutes. Fifty-nine (56%) dogs developed ventricular fibrillation and, before this test was repeated, were assigned either to a control group (n = 24) or to be instrumented with the vagal device (n = 35). Five dogs were excluded because of electrode malfunction. Compared with the heart rate level attained after 30 seconds of occlusion during exercise in the control test, vagal stimulation led to a decrease of approximately 75 beats/min (from 255 +/- 33 to 170 +/- 36 beats/min, p less than 0.001). In the control group 22 (92%) of 24 dogs developed ventricular fibrillation during the second exercise and ischemia test. By contrast, during vagal stimulation ventricular fibrillation occurred in only 3 (10%) of the 30 dogs tested and recurred in 26 (87%) during an additional exercise and ischemia test in the control condition (p less than 0.001 versus the vagal stimulation test; internal control analysis). Combined analysis of the tests performed in the control condition showed that ventricular fibrillation was reproducible in 48 (89%) of the 54 dogs tested. The protective effect of vagal stimulation was also significant in the group comparison analysis and even after exclusion of those four dogs in which ventricular fibrillation was not reproducible (92% versus 11.5%, control versus vagal stimulation, p less than 0.001). When heart rate was kept constant by atrial pacing, the vagally mediated protection was still significant (p = 0.015) as five (55%) of nine dogs survived the test. This study shows that vagal stimulation, performed shortly after the onset of an acute ischemic episode in conscious animals with a healed myocardial infarction, can effectively prevent ventricular fibrillation. This striking result seems to depend on multiple mechanisms having a synergistic action. The decrease in heart rate is an important but not always essential protective mechanism. The electrophysiological effects secondary to the vagally mediated antagonism of the sympathetic activity on the heart are likely to play a major role.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 597 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3