Heterogeneous changes in epimyocardial microvascular size during graded coronary stenosis. Evidence of the microvascular site for autoregulation.

Author:

Kanatsuka H1,Lamping K G1,Eastham C L1,Marcus M L1

Affiliation:

1. Department of Internal Medicine, College of Medicine, University of Iowa, Iowa City 52242.

Abstract

The purpose of this study was to determine the coronary microvascular sites of autoregulation. The epimyocardial coronary microcirculation was observed through an intravital microscope by stroboscopic epi-illumination in anesthetized open-chest dogs (n = 20). Aortic pressure and heart rate were held constant by an aortic snare and atrial pacing, respectively. Distal pressure of the left anterior descending coronary artery was controlled by a screw occluder on the proximal left anterior descending coronary artery and monitored with a 24-gauge plastic cannula inserted into the branch or distal portion of the left anterior descending coronary artery. Distal pressure of the left anterior descending coronary artery was stepwisely reduced to 59 +/- 1 mm Hg (mild stenosis, n = 20) and 38 +/- 1 mm Hg (severe stenosis, n = 16). In the left circumflex coronary artery area, myocardial blood flow measured with radioactive microspheres to subepicardium, midmyocardium, and subendocardium did not change with the mild and severe stenosis from control. In the left anterior descending coronary artery area, myocardial blood flow to each layer remained at nearly control level with the mild stenosis but was reduced in midmyocardium and subendocardium with the severe stenosis. With the mild stenosis, diameters of coronary arterial microvessels less than 100 microns in diameter dilated, and those larger than 100 microns in diameter did not change. The magnitude of vasodilation in small arterial microvessels was inversely related to control diameter. With the severe stenosis, small arterial microvessels dilated, and simultaneously, large arterial microvessels constricted. Again, the magnitude of vasodilation in small arterial microvessels was inversely related to control diameter.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference41 articles.

1. Regulation of Coronary Blood Flow

2. Autoregulation of the coronary circulation

3. Autoregulation of intestinal blood flow;Johnson PC;Am J Physiol,1960

4. Microvascular distribution of coronary vascular resistance in the beating left ventricle;Chilian WM;Am J Physiol,1986

5. Small coronary vessel pressure and diameter in an intact beating rabbit heart using fixed-position and free-motion techniques.

Cited by 130 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3