Carotid sinus baroreceptor reflex in dogs with experimental heart failure.

Author:

Wang W1,Chen J S1,Zucker I H1

Affiliation:

1. Department of Physiology and Biophysics, University of Nebraska College of Medicine, Omaha 68198-4575.

Abstract

We have previously demonstrated a decrease in baroreceptor discharge sensitivity in dogs with experimental heart failure. In the present study, we determined the sensitivity of the carotid sinus baroreceptor reflex in dogs with pacing-induced heart failure. The carotid sinus baroreceptor reflex sensitivity was determined by pressurizing one carotid sinus with all other baroreceptor and cardiopulmonary receptor inputs removed. The data were analyzed by plotting carotid sinus pressure-mean arterial pressure curves and carotid sinus pressure-renal sympathetic nerve activity curves in the two groups of dogs. The peak arterial pressure during carotid hypotension was significantly depressed in dogs with heart failure compared with normal dogs (107.1 +/- 5.7 versus 139.8 +/- 7.0 mm Hg, p less than 0.001). Mean arterial pressure range, renal sympathetic nerve activity range, and peak slope were significantly decreased in the heart-failure group. To determine if this depression was completely due to depression of baroreceptor discharge per se, or to alterations in central or end-organ responsiveness, similar experiments were performed by stimulating the carotid sinus nerve and evaluating frequency, voltage, and duration of stimulation on the resultant mean arterial pressure and renal sympathetic nerve activity. As was the case with carotid sinus pressurization, electrical stimulation caused a significantly smaller change in mean arterial pressure in heart-failure dogs compared with the normal dogs. However, there was no significant difference between normal and heart-failure dogs for the renal sympathetic nerve activity-electrical stimulation curves. These data strongly suggest that the depressed carotid sinus baroreceptor reflex in heart failure is not solely the result of depressed baroreceptor responsiveness but may be related to poor end-organ responses and normal central control of renal sympathetic outflow.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 85 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3