Characteristics of flow-mediated brachial artery vasodilation in human subjects.

Author:

Sinoway L I1,Hendrickson C1,Davidson W R1,Prophet S1,Zelis R1

Affiliation:

1. Division of Cardiology, Milton S. Hershey Medical Center, Pennsylvania State University, Hershey 17033.

Abstract

In an effort to determine whether arterial conductance vessels dilate in response to increased blood flow stimuli, brachial artery area (cm2) and diameter (cm) were derived by simultaneous measurement of forearm blood flow (ml/min.100 ml) and brachial artery blood flow velocity (cm/sec) following the release of arterial occlusion. Measurements were made at rest and at the time of maximal flow after the release of graded periods of forearm arterial occlusion (20 seconds to 10 minutes). These studies showed a graded large vessel dilation following occlusions of up to 1 minute (baseline diameter, 0.33 +/- 0.01; after 1 minute occlusion, 0.45 +/- 0.02 cm; p less than 0.05) after which time diameter plateaued (after 10 minutes of occlusion, 0.48 +/- 0.02 cm). In addition, the time course of diameter and flow changes after 3 minutes of arterial occlusion were examined. Flow was maximal at 5 seconds but diameter was maximal at 15-30 seconds after release. Furthermore, the half time for the return of diameter to baseline was longer than that for blood flow. We also measured the diameter after forearm heating (42 degrees C) and noted a substantial increase in diameter (before heating, 0.32 +/- 0.01; after heating, 0.39 +/- 0.02 cm; p less than 0.05). Finally, we applied pressure to the venous side of arteriovenous fistulae in five hemodialysis patients. This maneuver was associated with large reductions in forearm blood flow (baseline flow, 63.3 +/- 10.6; venous compression flow, 36.0 +/- 4.4 ml/min.100 ml; p less than 0.05) and a decrease in brachial artery size (baseline diameter, 0.63 +/- 0.07; venous compression diameter, 0.58 +/- 0.06 cm; p less than 0.05). We conclude that 1) the human brachial artery size changes in response to changes in blood flow, and 2) the maximal dilation occurs after maximal flow is noted. Although alternate explanations are possible for each of our observations, our results are most consistent with a flow-mediated, localized vasodilating process.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Cited by 112 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3