Lack of alerting reactions to intermittent cuff inflations during noninvasive blood pressure monitoring.

Author:

Parati G,Pomidossi G,Casadei R,Mancia G

Abstract

Intermittent noninvasive blood pressure monitoring is becoming increasingly popular because of the belief that a daytime blood pressure profile can provide a better clinical evaluation of hypertension than that provided by casual blood pressure measurements. This approach has potential limitations, however, one of which is that the cuff inflations permitting blood pressure to be repeatedly measured may induce an alerting reaction and a pressor response in the patients and lead to an overestimation of their daytime blood pressure. Blood pressure in 22 subjects was invasively recorded for 24 hours by the Oxford method. During the day of the recording blood pressure was also measured by a noninvasive device (Vita-Stat 901), which had its cuff applied to the opposite arm from which the intra-arterial signal was derived. For 2 hours the device provided automatic cuff inflations at 10-minutes intervals. For another 2 hours it was programmed to provide cuff inflations only following patients' commands, also at 10-minute intervals. Analysis of the intra-arterial blood pressure trace during the periods preceding and following the automatically or semiautomatically induced cuff inflations showed that these procedures caused no increment in systolic and diastolic blood pressure. This finding applied not only to the mean data but also to each individual measurement considered separately, including the initial one. Our results indicate that automatic and semiautomatic blood pressure monitorings do not induce an alarm reaction and a blood pressure rise and thus do not overestimate daytime blood pressure values.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Reference11 articles.

1. The Prognostic Value of Ambulatory Blood Pressures

2. Contribution of ambulatory blood pressure to the assessment of patients with mild to moderate elevation of office blood pressure;Sokolow M;Cardiovasc Rev Rep,1980

3. Methods for assessing blood pressure values in humans;Mancia G;Hypertension,1983

Cited by 134 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3