Transmission of the Blood Flow Pulse through the Pulmonary Arterial Tree of the Dog

Author:

KARATZAS NICHOLAS B.1,NOBLE MARK I.M.1,SAUNDERS KENNETH B.1,MCLLROY MALCOLM B.1

Affiliation:

1. Cardiovascular Research Institute, University of California San Francisco Medical Center San Francisco, California 94122

Abstract

We have made simultaneous measurements of the instantaneous flow in the main pulmonary artery using an electromagnetic flowmeter and the pulmonary capillaries using the nitrous oxide body plethysmograph method in six lightly anesthetized and spontaneously breathing dogs. We measured the transmission of the flow wave in the pulmonary arterial tree at a variety of heart rates and during alveolar hypoxia. Fourier analysis enabled us to study transmission in the intact animal in a way similar to that of imposed oscillations of flow in the isolated organ. The amplitude of the pulmonary capillary flow pulse was approximately half that in the main pulmonary artery. There was progressive decrease in amplitude from the first to the fourth harmonic in both the pulmonary arterial and pulmonary capillary flow pulses. Harmonics above the fourth were small and variable in amplitude. Transmission between pulmonary valve and capillaries was independent of heart rate. Hypoxia did not affect transmission. Assuming that the increase in resistance in this instance was due to precapillary vasoconstriction, this finding suggests that other factors may offset the effect of increase in resistance upon transmission.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference8 articles.

1. Pulmonary capillary blood flow and gas exchange. In Pulmonary Structure and Function, edited by A.V.S. de Reuck and M. O'Connor. Boston;SONI J.;Little Brown & Co.,1962

2. KARATZAS N. B.: Pulsatile pulmonary blood flow in health and in disease. D. Phil. Thesis University of Oxford 1967.

3. A pressure plethysmograph with a pneumatic differentiator for pulmonary capillary flow measurements

4. The relation of pulsatile pressure to flow in arteries

5. Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Vascular Dysfunction in Hypertension Revealed by Fourier Analysis of Aortic Blood Flow;Cardiovascular Engineering and Technology;2013-04-16

2. Pulmonary artery pulsatility is the main cause of cardiogenic oscillations;Journal of Clinical Monitoring and Computing;2012-08-22

3. A model of the pulmonary arterial bed in adults and infants;Computers and Biomedical Research;1990-04

4. Biofeedback;Psychologische Schmerztherapie;1990