Velocity Profiles in the Main Pulmonary Artery of Dogs and Man, Measured with a Thin-Film Resistance Anemometer

Author:

REUBEN S. R.1,SWADLING J. P.1,LEE G. DE J.1

Affiliation:

1. Cardiac Department and Nuffield Department of Medicine, Radcliffe Infirmary Oxford, England

Abstract

Instantaneous velocity of pulmonary artery blood was measured using a thin-film resistance anemometer mounted on a hypodermic needle. Studies were performed, at thoracotomy, in five dogs and five patients. Instantaneous blood velocity was recorded at several sites across the transverse axis of the main pulmonary artery to determine the shape of the velocity profile. We found the velocity profile, in both man and dog, to be approximately flat. In dog, the mean velocity, normalized to that at the center line, ranged from 1.18 (SD ± 0.03) to 0.81 (SD ± 0.27). In man, mean velocity of pulmonary artery blood, normalized in a similar fashion, ranged from 1.08 (SD ± 0.03) to 0.84 (SD ±0.07), while the normalized peak systolic velocity ranged from 1.04 (SD ± 0.07) to 0.95 (SD ± 0.16). The results, in dogs, suggest that there is little asymmetry of the velocity profile and therefore these have been taken as evidence that the use of cuff electromagnetic flowmeters on the pulmonary artery of dogs is not subject to significant inaccuracies associated with a nonsymmetrical flow profile. The finding of a relatively flat velocity profile in patients, moreover, will make it easier for catheter-tip flowmeters to measure bulk velocity in the pulmonary artery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference11 articles.

1. Velocity distribution and transition in the arterial system. In Ciba Foundation Symposium on Circulatory and Respiratory Mass Transport, edited by G. E. W. Wolstenholme and Julie Knight. London;SCHULTZ D. L.;J. & A. Churchill,1969

2. TUNSTALL PEDOE D. S.: Velocity distribution of blood flow in major arteries of animals and man. D. Phil. Thesis University of Oxford 1970.

3. Problems in the Measurement of Blood Flow by Magnetic Induction

4. GOLDMAN S. C. MARPLE N. B. AND SCOLNICK W. L.: Effects of flow profile on electromagnetic flowmeter accuracy. J Appl Physio! 18: 652 1963.

5. BERCEL D. H. AND GESSNER U.: The Electro

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3