Affiliation:
1. From the Institute of Diagnostic Radiology (G.F., A.S., F.W., J.M., M.C., A.A.) and Department of Neurology (T.N.-H., M. Schroeder), Heinrich-Heine-University Düsseldorf, and the Department of Neurology (H.S., M. Sitzer), J.W. Goethe University, Frankfurt am Main, Germany.
Abstract
Background and Purpose
—Our study evaluated noninvasive tests for the diagnosis of atheromatous internal carotid artery (ICA) pseudo-occlusion.
Methods
—Twenty patients (17 men, 3 women; mean age ±SD, 64.3±11.6 years) with angiographically proven atheromatous ICA pseudo-occlusion (20 vessels) were prospectively examined with MR angiography (MRA; 2D and 3D time-of-flight techniques), color Doppler–assisted duplex imaging (CDDI) and power-flow imaging (PFI) with and without an intravenous ultrasonic contrast agent. As a control group, 13 patients (13 men; mean±SD age, 63.0±9.0 years) with angiographically proven ICA occlusion (13 vessels) were studied with the same techniques. For the determination of interobserver agreement (κ statistics), the findings of each diagnostic technique were read by 2 blinded and independent observers who were not involved in patient recruitment and initial data acquisition. Specificity and sensitivity were calculated for all noninvasive techniques (observer consensus) in comparison to the standard of reference (intra-arterial angiography).
Results
—Interobserver reliabilities were κ=0.86 for intra-arterial angiography, κ=0.90 for unenhanced CDDI, κ=0.93 for enhanced CDDI, κ=0.93 for unenhanced PFI, κ=1.0 for enhanced PFI, κ=0.93 for 2D MRA, and κ=0.77 for 3D MRA, respectively (
P
<0.0001). Specificities and sensitivities were 0.92 and 0.70 for unenhanced CDDI, 0.92 and 0.83 for enhanced CDDI, 0.92 and 0.95 for unenhanced PFI, 1.0 and 0.94 for enhanced PFI, 1.0 and 0.65 for 2D MRA, and 0.89 and 0.47 for 3D MRA, respectively.
Conclusions
—Advanced ultrasonographic techniques, especially PFI (with only 1 false-positive diagnosis of occlusion in the present series), can provide reliable and valid data to differentiate between ICA pseudo-occlusion and complete occlusion. In contrast, time-of-flight MRA at its present state is not capable of predicting minimal residual flow within a nearly occluded ICA.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Subject
Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology
Cited by
111 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献