Methodological Parameters Influence the Detection of Right-to-Left Shunts by Contrast Transcranial Doppler Ultrasonography

Author:

Schwarze J. J.1,Sander D.1,Kukla C.1,Wittich I.1,Babikian V. L.1,Klingelhöfer J.1

Affiliation:

1. From the Department of Neurology, Technical University, Munich, Germany (J.J.S., D.S., C.K., I.W., J.K.), and Department of Neurology, Boston University School of Medicine, Boston, Mass (V.L.B.).

Abstract

Background and Purpose —Contrast transcranial Doppler ultrasonography is a new method to detect intracardiac right-to-left shunts, such as the patent foramen ovale. However, the methodology of the procedure varies considerably among investigators. This study was undertaken to assess the influence of methodological parameters on the results of the contrast transcranial Doppler examination in the detection of right-to-left shunts. Methods —A total of 72 patients (mean age, 58.2±14.7 years) had a contrast transcranial Doppler ultrasonography examination. To study the influence of methodological factors, patients with evidence of a right-to-left shunt underwent repeated examinations with modified procedures. Parameters under investigation were the timing of the Valsalva maneuver, the dose of the contrast medium, and the patient’s posture during the examination. Results —The median contrast signal count was 58.5 and 48.0 ( P <0.001) and the median latency of the first intracranially detected contrast signal was 12.5 and 8.5 seconds ( P =0.05) when the Valsalva maneuver was performed 5 and 0 seconds after the start of the injection, respectively. Reducing the contrast medium dose from 10 to 5, 2.5, and 1.2 mL resulted in a decline of the median signal count from 54.5 to 28.5, 20.5, and 12.0 ( P <0.01), respectively, while the latency of the first contrast signal increased from 13.3 to 14.0, 14.6, and 15.0 seconds ( P <0.05). The sitting position also produced a lower signal count than the supine position ( P <0.02). Conclusions —This study demonstrates that several essential methodological parameters influence the results of the contrast transcranial Doppler ultrasonography examination. Therefore, it is necessary to standardize the procedure to permit comparable quantitative assessments of the shunt volume. The findings of the present study suggest that 10 mL of contrast medium be injected with the patient in the supine position and that the Valsalva maneuver be performed 5 seconds after the start of the injection.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3