Early [11C]Flumazenil/H2O Positron Emission Tomography Predicts Irreversible Ischemic Cortical Damage in Stroke Patients Receiving Acute Thrombolytic Therapy

Author:

Heiss Wolf-Dieter1,Kracht Lutz1,Grond Martin1,Rudolf Jobst1,Bauer Bernd1,Wienhard Klaus1,Pawlik Gunter1

Affiliation:

1. From the Max-Planck Institut für neurologische Forschung and Neurologische Universitätsklinik, Cologne, Germany.

Abstract

Background and Purpose—Central benzodiazepine receptor ligands, such as [11C]flumazenil (FMZ), are markers of neuronal integrity and therefore might be useful in the differentiation of functionally and morphologically damaged tissue early in ischemic stroke. We sought to assess the value of a benzodiazepine receptor ligand for the early identification of irreversible ischemic damage to cortical areas that cannot benefit from reperfusion.Methods—Eleven patients (7 male, 4 female, aged 52 to 75 years) with acute, hemispheric ischemic stroke were treated with alteplase (recombinant tissue plasminogen activator; 0.9 mg/kg according to National Institute of Neurological Disorders and Stroke protocol) within 3 hours of onset of symptoms. At the beginning of thrombolysis, cortical cerebral blood flow ([15O]H2O) and FMZ binding were assessed by positron emission tomography (PET). Those early PET findings were related to the change in neurological deficit (National Institutes of Health Stroke Scale) and to the extent of cortical damage on MRI or CT 3 weeks after the stroke.Results—Hypoperfusion was observed in all cases, and in 8 patients the values were below critical thresholds estimated at 12 mL/100 g per minute, comprising 1 to 174 cm3of cortical tissue. Substantial reperfusion was seen in most of these regions 24 hours after thrombolysis. In 4 cases, distinct areas of decreased FMZ binding were detected. Those patients suffered permanent lesions in cortical areas corresponding to their FMZ defects (112 versus 146, 3 versus 3, 2 versus 1, and 128 versus 136 cm3). In the other patients no morphological defects were detected on MRI or CT, although blood flow was critically decreased in areas ranging in size up to 78 cm3before thrombolysis.Conclusions—These findings suggest that imaging of benzodiazepine receptors by FMZ PET distinguishes between irreversibly damaged and viable penumbra tissue early after acute stroke.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 128 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3