Collateral Configuration of the Circle of Willis

Author:

Hoksbergen A. W. J.1,Fülesdi B.1,Legemate D. A.1,Csiba L.1

Affiliation:

1. From the Departments of Neurology (A.W.J.H., L.C.), and Anesthesiology and Intensive Care (B.F.), University Medical School of Debrecen, Hungary, and the Department of Vascular Surgery, Academic Medical Center, Amsterdam, Netherlands (A.W.J.H., D.A.L.).

Abstract

Background and Purpose —The anterior communicating artery (AcoA) and posterior communicating arteries (PcoA) of the circle of Willis provide the main route for collateral blood flow in cases of carotid artery obstruction. Transcranial color-coded duplex ultrasonography (TCCD) allows real-time measurement of the collateral function of the AcoA and PcoA. The primary objective of this study was to determine the collateral artery threshold diameters for supplying collateral flow. Methods —In 12 acute stroke patients with a median age of 75 years (51 to 91 years), the collateral integrity of the circle of Willis as assessed by TCCD and carotid compression tests was compared with their postmortem anatomy. The lengths and diameters of the collateral arteries were measured. Results —TCCD demonstrated absent anterior collateral flow in 3 patients. In 1 of these patients, absence of anterior cross-flow was due to an occluded anterior cerebral artery, which was revealed at autopsy. Absent posterior collateral flow was found in 14 hemispheres. In 2 of these hemispheres, autopsy revealed a fetal configuration of the posterior cerebral artery hampering posterior collateral flow. The median (range) diameters as found at autopsy of the functional (n=19) and nonfunctional (n=16) collateral arteries of the circle of Willis were 1.1 (0.4 to 2.0) and 0.5 (0.3 to 0.7) mm, respectively ( P =0.003). PcoA diameters were found to correlate negatively (ρ=−0.50, P =0.01) to the diameters of their accessory P1 segments. Conclusions —The threshold diameter allowing for cross-flow through the primary collateral arteries of the circle of Willis is between 0.4 and 0.6 mm.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3