Identification Of Echocardiographic “Smoke” in a Bench Model With Transcranial Doppler Ultrasound

Author:

Yang Yi1,Grosset Donald G.1,Li Qiu1,Lees Kennedy R.1

Affiliation:

1. From the Neurology Division, Department of Medicine, University of Alberta, Alberta, Canada (Y.Y., Q.L.); Department of Neurology, Southern General Hospital, Glasgow, UK (D.G.G.); and the Department of Medicine and Therapeutics, University of Glasgow, Glasgow, Scotland, UK (K.R.L.).

Abstract

Background and Purpose —Spontaneous echo contrast in cardiac chamber has been indicated as a source of cerebral embolism. The nature of the echocardiographic smokelike signal is still not fully understood. This study was designed to regenerate spontaneous echo contrast and verify its thromboembolic characters in an in vitro model. Methods —Spontaneous echo contrast was reproduced in an expansion chamber under low flow conditions in a close circulation system. The spontaneous echo contrast was monitored and recorded with a 2-dimensional cardiosonography system and a transcranial Doppler device. Meanwhile, clinically commonly encountered embolic materials such as whole-blood clots, platelet aggregate–rich plasma, air bubbles, and 100-mL normal saline were injected into this monitored circuit. The differentiation of spontaneous echo contrast from emboli was performed by both visual observations of the echo images and offline Doppler signal intensity analysis. Average signal intensities produced by spontaneous contrast and injection of embolic materials and saline were compared. Furthermore, the effect of Doppler-detected flow velocity on generation of spontaneous contrast was also evaluated. Results —Spontaneous echo contrast was reproduced at low flow settings (90 to 120 mL/min) in this model. There was no significant difference in average signal intensity between the flow with spontaneous echo contrast and that without the echo ( P =0.71). However, injection of embolic materials or normal saline did not generate smokelike image but caused much higher average signal intensity than the flow with spontaneous contrast ( P <0.001). Injection of normal saline also increased average signal intensity. Conclusions —Our results suggest that smokelike echo is a special echo phenomenon occurring at low flow situations and does not itself produce material capable of embolizing into the systemic circulation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3