Cerebrovascular Reserve in Patients With Carotid Occlusive Disease Assessed by Stable Xenon-Enhanced CT Cerebral Blood Flow and Transcranial Doppler

Author:

Pindzola Ronda R.1,Balzer Jeffrey R.1,Nemoto Edwin M.1,Goldstein Steven1,Yonas Howard1

Affiliation:

1. From the Departments of Neurological Surgery (R.R.P., J.R.B., E..N., H.Y.), Neurology (S.G.), and Radiology (H.Y.), University of Pittsburgh Medical Center, Pittsburgh, Penn.

Abstract

Background and Purpose Cerebrovascular reserve (CVR) by both transcranial Doppler ultrasonography (TCD) and quantitative cerebral blood flow (CBF) can identify subgroups of patients at increased risk for stroke. A direct comparison of CVR measurements obtained with both technologies in patients with cerebrovascular occlusive disease is lacking. Methods CVRs before and after acetazolamide administration (1 g IV) were measured by TCD insonation of the middle cerebral artery (MCA) and CBF obtained with stable xenon CT (Xe/CT) in 38 patients with carotid occlusive disease. Sensitivity/specificity calculations were based on 2 Xe/CT MCA values: an average over 4 levels and the level with the lowest percent change in CBF. Compromised CVR was defined as no reactivity or a decrease in reactivity. Results Using the analysis of the systolic TCD, we found that velocity changes compared with the average Xe/CT MCA CVR showed a sensitivity of 33%, specificity of 90.6%, positive predictive value of 54.5%, and negative predictive value of 80%. The sensitivity of TCD compared with the lowest Xe/CT CBF CVR was 35.5%, specificity and positive predictive values were 100%, and negative predictive value was 66.7%. The index of validity was between 72% and 76%. Conclusions TCD is much less sensitive than Xe/CT CBF in identifying patients with compromised CVR. This may be a result of the inability of TCD to identify patients with compromised reserves when their MCA blood flow comes from collateral sources. The lack of correlation between TCD and Xe/CT CBF for identifying patients with compromised CVR should be considered when stroke risk assessments are made by TCD.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 66 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3