Different Home Blood Pressure Thresholds to Predict Perfect 24-Hour Ambulatory Blood Pressure Control in Treated Hypertension Based on an “All-in-One” Device

Author:

Kario Kazuomi1ORCID,Tomitani Naoko1ORCID,Hoshide Satoshi1,Nishizawa Masafumi2,Yoshida Tetsuro3ORCID,Kabutoya Tomoyuki1ORCID,Fujiwara Takeshi1ORCID,Mizuno Hiroyuki1ORCID,Okawara Yukie1,Kanegae Hiroshi1,

Affiliation:

1. Department of Medicine, Division of Cardiovascular Medicine, Jichi Medical University School of Medicine, Tochigi, Japan (K.K., N.T., S.H., T.K., T.F., H.M., Y.O., H.K.).

2. Minamisanriku Hospital, Miyagi, Japan (M.N.).

3. Onga Nakama Medical Association Onga Hospital, Fukuoka, Japan (T.Y.).

Abstract

BACKGROUND: Home blood pressure (BP) is an important component of digital strategies for hypertension management. However, no studies have used the same device to investigate 24-hour BP control status in relation to different home BP control thresholds. METHODS: Participants in the general practitioner-based, multicenter HI-JAMP study (Home-Activity Information and Communication Technology-Based Japan Ambulatory Blood Pressure Monitoring Prospective) underwent office BP measurement, then 24-hour ambulatory BP monitoring, then home BP monitoring for 5 days. A validated all-in-one BP monitoring device was used to measure office, home, and ambulatory BP. Baseline data were used to investigate ambulatory BP control status in individuals with well-controlled home BP based on the different guideline thresholds (125/75 mm Hg, 130/80 mm Hg, and 135/85 mm Hg). RESULTS: Data from 2269 patients were analyzed. For individuals with well-controlled home BP <135/85 mm Hg (59.5% of the total population), the prevalence of uncontrolled 24-hour (≥130/80 mm Hg), daytime (≥135/85 mm Hg), and nighttime ambulatory BP (≥120/70 mm Hg) was 19.9%, 18.5%, and 33.6%, respectively. Corresponding prevalence rates in the 42.7% of participants with well-controlled home BP <130/80 mm Hg were 13.4%, 12.9%, and 26.0%, and when well-controlled home BP was strictly defined as <125/75 mm Hg (23.9% of the population), prevalence of rates of uncontrolled 24-hour, daytime, and nighttime ambulatory BP were 7.0%, 9.0%, and 15.3%, respectively. CONCLUSIONS: Home BP control status defined using different thresholds could predict 24-hour ambulatory BP control status in treated hypertension. One-third of individuals still had uncontrolled nocturnal hypertension when home BP was controlled to <135/85 mm Hg, but ambulatory BP was quite well controlled when home BP was <125/75 mm Hg.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3