Effects of Baroreflex Activation Therapy on Ambulatory Blood Pressure in Patients With Resistant Hypertension

Author:

Wallbach Manuel1,Lehnig Luca-Yves1,Schroer Charlotte1,Lüders Stephan1,Böhning Enrico1,Müller Gerhard A.1,Wachter Rolf1,Koziolek Michael J.1

Affiliation:

1. From the Department of Nephrology and Rheumatology (M.W., L.-Y.L., C.S., E.B., G.A.M., M.J.K.) and Department of Cardiology and Pulmonology (R.W.), Georg-August-University Göttingen, Göttingen, Germany; and St. Josefs Hospital, Cloppenburg, Germany (S.L.).

Abstract

Baroreflex activation therapy (BAT) has been demonstrated to decrease office blood pressure (BP) in the randomized, double-blind Rheos trial. There are limited data on 24-hour BP changes measured by ambulatory BP measurements (ABPMs) using the first generation rheos BAT system suggesting a significant reduction but there are no information about the effect of the currently used, unilateral BAT neo device on ABPM. Patients treated with the BAT neo device for uncontrolled resistant hypertension were prospectively included into this study. ABPM was performed before BAT implantation and 6 months after initiation of BAT. A total of 51 patients were included into this study, 7 dropped out from analysis because of missing or insufficient follow-up. After 6 months, 24-hour ambulatory systolic (from 148±17 mm Hg to 140±23 mm Hg, P <0.01), diastolic (from 82±13 mm Hg to 77±15 mm Hg, P <0.01), day- and night-time systolic and diastolic BP (all P ≤0.01) significantly decreased while the number of prescribed antihypertensive classes could be reduced from 6.5±1.5 to 6.0±1.8 ( P =0.03). Heart rate and pulse pressure remained unchanged. BAT was equally effective in reducing ambulatory BP in all subgroups of patients. This is the first study demonstrating a significant BP reduction in ABPM in patients undergoing chronically stimulation of the carotid sinus using the BAT neo device. About that BAT-reduced office BP and improved relevant aspects of ABPM, BAT might be considered as a new therapeutic option to reduce cardiovascular risk in patients with resistant hypertension. Randomized controlled trials are needed to evaluate BAT effects on ABPM in patients with resistant hypertension accurately.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3