Effect of SR Manipulation on Conduit Artery Dilation in Humans

Author:

Carter Howard H.1,Dawson Ellen A.1,Birk Gurpreet K.1,Spence Angela L.1,Naylor Louise H.1,Cable N. Timothy1,Thijssen Dick H.J.1,Green Daniel J.1

Affiliation:

1. From the School of Sport Science, Exercise, and Health, University of Western Australia, Crawley, Western Australia, Australia (H.H.C., A.L.S., L.H.N., D.J.G.); Research Institute for Sport and Exercise Science, Liverpool John Moores University, Liverpool, United Kingdom (E.A.D., G.K.B., N.T.C., D.H.J.T., D.J.G.); and Department of Physiology, Radboud University Nijmegen Medical Centre, Radboud, the Netherlands (D.H.J.T.).

Abstract

The impact of manipulating shear stress on conduit artery vasodilation has not been comprehensively described in vivo. We hypothesized that manipulation of SR through the brachial and radial arteries would be associated with corresponding changes in diameter. We performed a series of studies involving the following: (1) leg cycle exercise at increasing intensities (≈70 and 85% maximum heart rate [HRmax]) with simultaneous bilateral measurement of SR in the radial arteries; (2) leg cycle exercise for 30 minutes at 80% HRmax with simultaneous bilateral measurement of velocity and diameter in the brachial arteries; and (3) bilateral forearm heating for 30 minutes with simultaneous bilateral measurement of brachial artery diameter and blood velocity. Cycling and forearm heating interventions were performed in the presence of unilateral cuff inflation throughout the experiment, or starting during the intervention (15 minutes), to manipulate SR responses. Cuff placement was associated with lower radial artery SR responses (cuffed versus uncuffed, 248±49 versus 349±105 L/s 85% HRmax; P <0.01), and diameter responses were similarly attenuated (2.45±0.30 versus 2.78±0.20 mm 85% HRmax; P <0.05). Exercise performed at 80% HRmax in the presence of unilateral cuff inflation also reduced brachial artery SR (cuffed versus uncuffed; 258±107 versus 454±157 L/s; P <0.01) and diameter (3.96±0.39 versus 4.20±0.45 mm). Finally, cuff inflation decreased the impact of forearm heating on brachial SR (cuffed versus uncuffed; 262±97 versus 440±106 L/s; P <0.01) and diameter (4.35±0.54 versus 4.87±0.47 mm; P <0.05). Similar significant differences between the cuffed and uncuffed limbs in SR and diameter were observed when cuff inflation occurred during exercise or heating. Our findings strongly implicate SR as an important stimulus to increase conduit artery diameter in humans.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3