Blood Pressure Outcome of Angioplasty in Atherosclerotic Renal Artery Stenosis

Author:

Plouin Pierre-François1,Chatellier Gilles1,Darné Bernadette1,Raynaud Alain1

Affiliation:

1. From the Hypertension Department (P.-F.P.), Department of Medical Informatics (G.C., B.D.), and Department of Cardiovascular Radiology (A.R.), Hôpital Broussais, and INSERM U-36 (P.-F.P.), Paris, France.

Abstract

Abstract —Data for the effects on blood pressure of renal artery balloon angioplasty are mostly from uncontrolled studies. The aim of this study was to document the efficacy and safety of angioplasty for lowering blood pressure in patients with atherosclerotic renal artery stenosis. Patients were randomly assigned antihypertensive drug treatment (control group, n=26) or angioplasty (n=23). Twenty-four-hour ambulatory blood pressure, the primary end point, was measured at baseline and at termination. Termination took place 6 months after randomization or earlier in patients who developed refractory hypertension. In those allocated angioplasty, antihypertensive treatment was discontinued after the procedure but was subsequently resumed if hypertension persisted. Secondary end points were the treatment score and the incidence of complications. Two patients in the control group and 6 in the angioplasty group suffered procedural complications (relative risk, 3.4; 95% confidence interval, 0.8 to 15.1). Early termination was required for refractory hypertension in 7 patients in the control group. Antihypertensive treatment was resumed in 17 patients in the angioplasty group. Mean ambulatory blood pressure at termination did not differ between control (141±15/84±11 mm Hg) and angioplasty (140±15/81±9 mm Hg) groups. Angioplasty reduced by 60% the probability of having a treatment score of 2 or more at termination (relative risk, 0.4; 95% confidence interval, 0.2 to 0.7). There was 1 case of dissection with segmental renal infarction and 3 of restenosis in the angioplasty group. No patient suffered renal artery thrombosis. In unilateral atherosclerotic renal artery stenosis, angioplasty is a drug-sparing procedure that involves some morbidity. Previous uncontrolled and unblinded assessments of angioplasty overestimated its potential for lowering blood pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

Cited by 531 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3