Ambulatory Blood Pressure

Author:

Schettini Carlos1,Bianchi Manuel1,Nieto Fernando1,Sandoya Edgardo1,Senra Hugo1

Affiliation:

1. From the Department of Cardiology, Asociación Española Primera de Socorros Mutuos, Montevideo, Uruguay.

Abstract

Abstract —Previous studies have reported results on 24-hour ambulatory blood pressure (ABP) in Europe and Japan, but no data exists from South America. In this study, we conducted a population survey to identify reference values and to compare ambulatory blood pressure with clinic, home, and self-measured values. A random sample of 2650 adults was selected among 190 000 people covered by our prepaid healthcare institution. Clinic (physician and nurse) and home (nurse) blood pressure measurements were performed 3 times each, with semiautomatic electronic equipment. Self-measurements were performed by the subjects manually activating the ambulatory device. We analyzed 1573 individuals who were not receiving antihypertensive therapy from 1921 participants. Self-measurement was available in a subgroup of 577 participants younger than the whole sample. Normal ambulatory blood pressure limits were estimated as those that best correlated with 140/90 mm Hg at clinic. Estimated values were 125/80 mm Hg for 24-hour ambulatory (range: 122 to 128 and 77 to 83 mm Hg) and 129/84 mm Hg for daytime ambulatory (range: 127 to 132 and 81 to 86) blood pressure, depending on gender and age. Ambulatory and clinic blood pressures increased with age. The age-dependent increase in ABP was similar in women and men. Average blood pressure at clinic was 124/79 mm Hg by physician and 123/78 mm Hg by nurse. Nurse measurement at home was 125/78 mm Hg, daytime ambulatory was 121/77 mm Hg, and 24-hour ambulatory was 118/74 mm Hg. The values of the subgroup with self-measurement were physician 119/77 mm Hg; nurse at clinic 118/77 mm Hg; nurse at home 121/78 mm Hg; self-measured 115/72 mm Hg; daytime ambulatory 119/77 mm Hg; and 24-hour ambulatory 115/73 mm Hg. This study shows that a 24-hour ABP average value of 125/80 mm Hg and a daytime ABP average value of 129/84 mm Hg are suitable upper limits for normality. Higher limits would yield an artificially higher prevalence of white coat hypertension. Most subjects showed higher blood pressure levels when measurements were performed by healthcare personnel at a clinic or at home than when self-measured at home.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3