Multiple Clinic and Home Blood Pressure Measurements Versus Ambulatory Blood Pressure Monitoring

Author:

Jula Antti1,Puukka Pauli1,Karanko Hannu1

Affiliation:

1. From the Research and Development Center of the Social Insurance Institution, Turku, Finland.

Abstract

Abstract —To compare multiple clinic and home blood pressure (BP) measurements and ambulatory BP monitoring in the clinical evaluation of hypertension, we studied 239 middle-aged pharmacologically untreated hypertensive men and women who were referred to the study from the primary healthcare provider. Ambulatory BP monitoring was successfully completed for 233 patients. Clinic BP was measured by a trained nurse with a mercury sphygmomanometer and averaged over 4 duplicate measures. Self-recorded home BP was measured with a semiautomatic oscillometric device twice every morning and twice every evening on 7 consecutive days. Ambulatory BP was recorded with an auscultatory device. Two-dimensionally controlled M-mode echocardiography was successfully performed on 232 patients. Twenty-four–hour urinary albumin was determined by nephelometry. Clinic BP was 144.5±12.6/94.5±7.4 mm Hg, home BP (the mean of 14 self-recorded measures) was 138.9±13.1/92.9±8.6 mm Hg, home morning BP (the mean of the first 4 duplicate morning measures) was 137.1±13.7/92.4±9.2 mm Hg, daytime ambulatory BP was 148.3±13.9/91.9±7.8 mm Hg, nighttime ambulatory BP was 125.5±16.4/75.6±8.9 mm Hg, and 24-hour ambulatory BP was 141.7±14.0/87.2±7.6 mm Hg. Pearson correlation coefficients of clinic, home, home morning, and daytime ambulatory BPs to albuminuria and to the characteristics of the left ventricle were nearly equal. In multivariate regression analyses, 36% ( P <0.0001) of the cross-sectional variation in left ventricular mass index was attributed to gender and home morning systolic BP in models that originally included age, gender, and clinic, self-measured home morning, and ambulatory daytime, nighttime, and 24-hour systolic and diastolic BPs. We concluded that carefully controlled nonphysician-measured clinic and self-measured home BPs, when averaged over 4 duplicate measurements, are as reliable as ambulatory BP monitoring in the clinical evaluation of untreated hypertension.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3