Comparison of Dilution Technics Using Aortic Injection with Upstream Sampling for Assessment of Aortic Regurgitation

Author:

ARMELIN EGAS1,DONALD DAVID E.1,WOOD EARL H.1

Affiliation:

1. Mayo Clinic and Mayo Foundation, Rochester, Minnesota

Abstract

The distances between the aortic valve and sites in the aorta from which no retrograde flow of injected indicator could be detected in the left ventricle were determined, without thoracotomy, in two normal dogs and in ten dogs with chronic experimental aortic regurgitation. It was found that these distances attained maximal values when the aortic injections were timed to occur just at the end of systole or onset of diastole. Distances downstream from the origin of the left subclavian artery from which no retrograde flow occurred to this vessel were determined similarly in these same animals and, in confirmation of Warner and Toronto, similar relationships to the timing of the injections were obtained. These distances down the aorta, designated as "disappearance distances", were converted to "disappearance volumes" by measuring the diameters of the silhouette of successive aortic segments from aortograms made after contrast medium was injected into the left ventricle of these animals. The regurgitant flow through the aortic valve per heartbeat was estimated on the basis of the amount of immediately appearing indicator detected in the left ventricle following injection of indicator approximately 1 cm downstream from the aortic valve. Correlation coefficients of 0.88 and 0.77 were obtained between these stroke-regurgitation values and the disappearance volumes from the aortic valve and subclavian artery, respectively. The standard errors of the estimate of the regurgitant flow per beat from these regression equations were ± 2.7 and ± 2.9 ml/beat, respectively. The correlation coefficients between stroke-regurgitation values and the disappearance distances from the valve and subclavian artery were 0.83 and 0.81, respectively, and the respective standard errors of the estimate of stroke regurgitation from these regression equations were ± 3.2 and ± 3.3 ml/beat. It is concluded that determination of the maximal distances downstream in the aorta of sites from which retrograde flow of injected indicator can be detected in the left ventricle or subclavian artery is a valid method for estimating the severity of experimental aortic regurgitation in dogs. Since determinations of the disappearance distance from the aortic valve can be carried out readily in conjunction with measurement of the left ventricular regurgitation fraction, it is suggested that advantage be taken of the increase in reliability which accrues from the combined use of these two independent methods for the estimation of the degree of aortic regurgitation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,Physiology

Reference20 articles.

1. Detection and estimation of mitral regurgitation by indicator dilution technique, (abstr.) J;WOOD E. H.;Clin. Invest.,1956

2. Experimental analysis of an atrial sampling technic for quantitating mitral regurgitation;SINCLAIR J. D.;Proc. Staff Meetings Mayo Clinic,1960

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. REFERENCES;Acta Medica Scandinavica;2009-04-24

2. Estimation of Forward and Backward Mitral Flow Using Indicator Dilution Technique: A Theoretical Feasibility Study;Cardiovascular Engineering;2006-11-21

3. Detection and quantification of aortic regurgitation during aortic valvuloplasty;Catheterization and Cardiovascular Diagnosis;1990-05

4. Quantification of mitral valvular incompetence;Catheterization and Cardiovascular Diagnosis;1985

5. Assisted circulation with an auxiliary heart transplant;The Journal of Thoracic and Cardiovascular Surgery;1972-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3