Real-Time Continuous Monitoring of Cerebral Blood Flow Autoregulation Using Near-Infrared Spectroscopy in Patients Undergoing Cardiopulmonary Bypass

Author:

Brady Kenneth1,Joshi Brijen1,Zweifel Christian1,Smielewski Peter1,Czosnyka Marek1,Easley R. Blaine1,Hogue Charles W.1

Affiliation:

1. From the Department of Anesthesiology and Critical Care Medicine (K.B., B.J., R.B.E., C.W.H.), Johns Hopkins Hospital, Baltimore, Md; and the Department of Academic Neurosurgery (C.Z., P.S., M.C.), Addenbrookes Hospital, Cambridge, UK.

Abstract

Background and Purpose— Individualizing mean arterial blood pressure targets to a patient’s cerebral blood flow autoregulatory range might prevent brain ischemia for patients undergoing cardiopulmonary bypass (CPB). This study compares the accuracy of real-time cerebral blood flow autoregulation monitoring using near-infrared spectroscopy with that of transcranial Doppler. Methods— Sixty adult patients undergoing CPB had transcranial Doppler monitoring of middle cerebral artery blood flow velocity and near-infrared spectroscopy monitoring. The mean velocity index (Mx) was calculated as a moving, linear correlation coefficient between slow waves of middle cerebral artery blood flow velocity and mean arterial blood pressure. The cerebral oximetry index was calculated as a similar coefficient between slow waves of cerebral oximetry and mean arterial blood pressure. When cerebral blood flow is autoregulated, Mx and cerebral oximetry index vary around zero. Loss of autoregulation results in progressively more positive Mx and cerebral oximetry index. Results— Mx and cerebral oximetry index showed significant correlation ( r =0.55, P <0.0001) and good agreement (bias, 0.08±0.18, 95% limits of agreement: −0.27 to 0.43) during CPB. Autoregulation was disturbed in this cohort during CPB (average Mx 0.38, 95% CI 0.34 to 0.43). The lower cerebral blood flow autoregulatory threshold (defined as incremental increase in Mx >0.45) during CPB ranged from 45 to 80 mm Hg. Conclusions— Cerebral blood flow autoregulation can be monitored continuously with near-infrared spectroscopy in adult patients undergoing CPB. Real-time autoregulation monitoring may have a role in preventing injurious hypotension during CPB. Clinical Trials Registration— at www.clinicaltrials.gov (NCT00769691).

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3