Cerebral Embolic Protection Devices During Transcatheter Aortic Valve Implantation

Author:

Bagur Rodrigo1,Solo Karla1,Alghofaili Saleh1,Nombela-Franco Luis1,Kwok Chun Shing1,Hayman Samual1,Siemieniuk Reed A.1,Foroutan Farid1,Spencer Frederick A.1,Vandvik Per O.1,Schäufele Tim G.1,Mamas Mamas A.1

Affiliation:

1. From the Division of Cardiology, Department of Medicine, London Health Sciences Center (R.B., S.A., S.H.) and Department of Epidemiology and Biostatistics (R.B., K.S.), Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada; Keele Cardiovascular Research Group, Institute of Applied Clinical Science (R.B., C.S.K., M.A.M.), Keele University and Royal Stoke Hospital, Stoke-on-Trent, United Kingdom; Division of Cardiology, Hospital Clínico San Carlos, Madrid, Spain (L.N...

Abstract

Background and Purpose— Silent ischemic embolic lesions are common after transcatheter aortic valve implantation (TAVI). The use of embolic protection devices (EPD) may reduce the occurrence of these embolic lesions. Thus, a quantitative overview and credibility assessment of the literature was necessary to draw a robust message about EPD. Therefore, the aim of this meta-analysis was to study whether the use of EPD reduces silent ischemic and clinically evident cerebrovascular events associated with TAVI. Methods— We conducted a comprehensive search to identify studies that evaluated patients undergoing TAVI with or without EPD. Random-effects meta-analyses were performed to estimate the effect of EPD compared with no-EPD during TAVI using aggregate data. Results— Sixteen studies involving 1170 patients (865/305 with/without EPD) fulfilled the inclusion criteria. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. Meta-analyses evaluating EPD versus without EPD strategies could not confirm or exclude any differences in terms of clinically evident stroke (relative risk, 0.70; 95% confidence interval [CI], 0.38–1.29; P =0.26) or 30-day mortality (relative risk, 0.58; 95% CI, 0.20–1.64; P =0.30). There were no significant differences in new-single, multiple, or total number of lesions. The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, −0.52; 95% CI, −0.85 to −0.20; P =0.002) and smaller total volume of lesions (standardized mean difference, −0.23; 95% CI, −0.42 to −0.03; P =0.02). Subgroup analysis by type of valve showed an overall trend toward significant reduction in new lesions per patient using EPD (standardized mean difference, −0.41; 95% CI, −0.82 to 0.00; P =0.05), driven by self-expanding devices. Conclusions— The use of EPD during TAVI may be associated with smaller volume of silent ischemic lesions and smaller total volume of silent ischemic lesions. However, EPD may not reduce the number of new-single, multiple, or total number of lesions. There was only very low quality of evidence showing no significant differences between patients undergoing TAVI with or without EPD with respect to clinically evident stroke and mortality.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3