WEAVE Trial

Author:

Alexander Michael J.1,Zauner Alois2,Chaloupka John C.3,Baxter Blaise4,Callison Richard C.5,Gupta Rishi6,Song Shlee S.7,Yu Wengui8,Feng Lei,Bonovich David,Toth Gabor,Kott Brian,Veznedaroglu Erol,Ringer Andrew,Meyers Philip,Agola John,Ghodke Basavaraj,Alhajeri Abdulnasser,Fraser Justin,Given Curtis,de Valle Eric Lopez,Shah Qaisar,Nesbit Gary,Hassan Ameer,Grobelny Thomas,Fessler Richard,Shownkeen Harish,

Affiliation:

1. From the Department of Neurosurgery (M.J.A.), Cedars-Sinai Medical Center, Los Angeles, CA

2. Neuroscience Institute, Cottage Hospital, Santa Barbara, CA (A.Z.)

3. Division of NeuroInterventional Surgery, Mount Sinai Medical Center, Miami, FL (J.C.C.)

4. Department of Radiology, Erlanger Hospital, Chattanooga, TN (B.B.)

5. Neurosciences, SSM Medical Center, St Louis, MO (R.C.C.)

6. Neuroscience, WellStar Health System, Marietta, GA (R.G.)

7. Department of Neurology (S.S.S.), Cedars-Sinai Medical Center, Los Angeles, CA

8. Department of Neurology, University of California - Irvine Medical Center (W.Y.).

Abstract

Background and Purpose— The WEAVE trial (Wingspan Stent System Post Market Surveillance) is a postmarket surveillance trial mandated by the Food and Drug Administration to assess the periprocedural safety of the Wingspan Stent system in the treatment of symptomatic intracranial atherosclerotic disease. Methods— A total of 152 consecutive patients who met the Food and Drug Administration on-label usage criteria were enrolled at 24 hospitals and underwent angioplasty and stenting with the Wingspan stent. On-label criteria included age 22 to 80 years, symptomatic intracranial atherosclerotic stenosis of 70% to 99%, baseline modified Rankin Scale score ≤3, ≥2 strokes in the vascular territory of the stenotic lesion with at least 1 stroke while on medical therapy, and stenting of the lesion ≥8 days after the last stroke. The primary analysis assessed the periprocedural stroke, bleed, and death rate within 72 hours of the procedure with adjudication by a core study Stroke Neurologist. Results— The trial was stopped early after interim analysis of 152 consecutive patients demonstrated a lower than expected 2.6% (4/152 patients) periprocedural stroke, bleed, and death rate. This was lower than the 4% periprocedural primary event safety benchmark set for the interim analysis in the study. A total of 97.4% (148/152) patients were event-free at 72 hours, 1.3% (2/152) had nonfatal strokes, and 1.3% (2/152) of patients died. Conclusions— With experienced interventionalists, and proper patient selection following the on-label usage guidelines, the use of the Wingspan stent for intracranial atherosclerotic disease demonstrated a low periprocedural complication rate and excellent safety profile. This is the largest on-label, multicenter, prospective trial of the Wingspan stent system to date with the lowest reported complication rate. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT02034058.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3