Susceptibility-Weighted Imaging is More Reliable Than T2*-Weighted Gradient-Recalled Echo MRI for Detecting Microbleeds

Author:

Cheng Ah-Ling1,Batool Saima1,McCreary Cheryl R.1,Lauzon M.L.1,Frayne Richard1,Goyal Mayank1,Smith Eric E.1

Affiliation:

1. From the Department of Radiology (A.-L.C., C.R.M., M.L.L., R.F., M.G., E.E.S.), Seaman Family MR Research Centre (S.B., C.R.M., M.L.L., R.F., M.G., E.E.S.), Hotchkiss Brain Institute (R.F., M.G., E.E.S.), and Department of Clinical Neurosciences, University of Calgary, Calgary, Canada (E.E.S.).

Abstract

Background and Purpose— We investigated the sensitivity and reliability of MRI susceptibility-weighted imaging (SWI) compared with routine MRI T2*-weighted gradient-recalled echo (GRE) for cerebral microbleed (CMB) detection. Methods— We used data from a prospective study of cerebral amyloid angiopathy (n=9; mean age, 71±8.3) and healthy non–cerebral amyloid angiopathy controls (n=22; mean age, 68±6.3). Three raters (labeled 1, 2, and 3) independently interpreted the GRE and SWI sequences (using the phase-filtered magnitude image) blinded to clinical information. Results— In 9 cerebral amyloid angiopathy cases, the raters identified 1146 total CMBs on GRE and 1432 CMBs on SWI. In 22 healthy control subjects, the raters identified ≥1 CMBs in 6/22 on GRE (total 9 CMBs) and 5/22 on SWI (total 19 CMBs). Among cerebral amyloid angiopathy cases, the reliability between raters for CMB counts was good for SWI (intraclass correlation coefficient, 0.87) but only moderate for GRE (intraclass correlation coefficient, 0.52). In controls, agreement on the presence or absence of CMBs in controls was moderate to good on both SWI (κ coefficient ranged from 0.57 to 0.74 across the 3 combinations of rater pairs) and GRE (κ range, 0.31 to 0.70). A review of 114 hypointensities identified as possible CMBs indicated that increased detection and reliability on SWI was related to both increased contrast and higher resolution, allowing better discrimination of CMBs from the background and better anatomic differentiation from pial vessels. Conclusions— SWI confers greater reliability as well as greater sensitivity for CMB detection compared with GRE, and should be the preferred sequence for quantifying CMB counts.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Reference23 articles.

1. Histopathologic analysis of foci of signal loss on gradient-echo T2*-weighted MR images in patients with spontaneous intracerebral hemorrhage: evidence of microangiopathy-related microbleeds.;Fazekas F;AJNR Am J Neuroradiol,1999

2. Cerebral microbleeds: a guide to detection and interpretation

3. Clinical diagnosis of cerebral amyloid angiopathy: Validation of the Boston Criteria

4. Hemorrhage Burden Predicts Recurrent Intracerebral Hemorrhage After Lobar Hemorrhage

5. Course of cerebral amyloid angiopathy-related inflammation

Cited by 222 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3