Quantification of Microspheres Appearance in Brain Vessels

Author:

Sharma Vijay K.1,Tsivgoulis Georgios1,Lao Annabelle Y.1,Malkoff Marc D.1,Alexandrov Anne W.1,Alexandrov Andrei V.1

Affiliation:

1. From the Comprehensive Stroke Center (V.K.S., G.T., A.W.A., A.V.A.), University of Alabama at Birmingham; the National University Hospital (V.K.S.), Singapore; the Department of Neurology (G.T.), Eginition Hospital, University of Athens, Greece; and the Stroke and Critical Care Program (A.Y.L., M.D.M.), Barrow Neurological Institute, Phoenix, Ariz.

Abstract

Background and Purpose— Characteristics of ultrasound-activated gaseous microspheres (μS) reflective of their size and quantities are needed for future dose-escalation and drug delivery trials. Methods— A double-blind, interobserver-validated analysis of multi-gate power-motion Doppler μS traces included large (>8μ) μS from agitated saline injections in the right-to-left shunt (RLS) positive stroke patients and small (<5μ) μS from acute patients without shunts receiving thrombolysis and perflutren-lipid μS. Results— In 101 μS traces from 50 RLS-positive and 10 thrombolysis+μS treated patients, a large μS passage had median maximum duration 30.8 ms (interquartile range [IQR] 22.0ms), multi-gate travel time (MGTT) 58.6±19.3 ms versus small μS: duration 8.3ms (IQR 4.3ms), MGTT 43.2±13.9ms, P <0.001. Small μS had higher embolus-to-blood ratio (EBR): 17.5 (IQR 9.3) versus 7.5 (IQR 4), P <0.001. Receiver-operating curve areas were: duration 0.989 (95% CI 0.968 to 1.000), MGTT 0.766 (0.672 to 0.859), and EBR (Embolus-to-Blood Ratio) 0.927 (0.871 to 0.982), P <0.001. A 15.1-ms duration discriminated size ranges with 98% to 99% accuracy. On average, 130 sequential large (range 51 to 260) and 500 (265–588) small μS can produce continuous flow enhancement for 4 seconds. Small μS velocities on m-mode in obstructed vessels (39.8±11.3 cm/s) were similar to large μS in patent vessels (40.8±11.5 cm/s; P =0.719) and higher than surrounding red blood cell velocities (28.8±13.8 cm/s, P <0.001). Conclusions— With normal or reduced flow, activated μS passage duration through a small power motion Doppler gate can quantify the dose of delivered μS. Ultrasound can determine a minimum number of μS needed to achieve constant flow enhancement and targeted drug delivery. Propagation speed of μS smaller than red blood cells may reflect plasma flow velocities around acute occlusions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3