Comparison of Methods for Magnetic Resonance-Guided [18-F]Fluorodeoxyglucose Positron Emission Tomography in Human Carotid Arteries

Author:

Izquierdo-Garcia David1,Davies John R.1,Graves Martin J.1,Rudd James H.F.1,Gillard Jonathan H.1,Weissberg Peter L.1,Fryer Tim D.1,Warburton Elizabeth A.1

Affiliation:

1. From Wolfson Brain Imaging Centre (D.I.-G., T.D.F.), Division of Cardiovascular Medicine (J.R.D., J.H.F.R., P.L.W.), Department of Radiology (M.J.G., J.H.G.), Clinical Neurosciences (E.A.W.), University of Cambridge, Addenbrooke’s Hospital, Cambridge, UK.

Abstract

Background and Purpose— Inflammation is a major risk factor for atherosclerotic plaque rupture and clinical events. Previous studies have shown that plaque [ 18 F]fluorodeoxyglucose (FDG) uptake correlates with macrophage content. In this study we examined the reproducibility of 3 methods of quantifying plaque FDG uptake in the carotid arteries using positron emission tomography (PET). The correlation between 2 simplified uptake parameters (standardized uptake value [SUV], vessel wall-to-blood ratio [VBR]) and a gold standard technique (influx rate [K i ]) was also determined. We used MRI to correct carotid plaque FDG uptake for partial volume error. Methods— Seven patients with a recent carotid territory transient ischemic attack underwent imaging twice within 8 days using MR and FDG-PET. MR coregistered to PET was used to delineate regions of interest, and to facilitate partial volume correction (PVC). Results— SUV was the most reproducible parameter irrespective of whether it was normalized by body surface area (BSA), lean body mass, or weight (intraclass correlation coefficient=0.85, 0.88, and 0.90, respectively). VBR correlated better to K i than SUV ( r =0.58 VBR, r =0.46 SUV BSA ). PVC improved these correlations to r =0.81 VBR and r =0.76 SUV BSA , and only slightly degraded the reproducibility of SUV (intraclass correlation coefficient=0.83–0.85). Conclusions— MR-guided FDG-PET is a highly reproducible technique in the carotid artery and the excellent anatomic detail provided by MR facilitates PVC. Of the methods examined, SUV BSA PVC appears to represent the best compromise between reproducible and accurate determination of FDG metabolism in carotid artery vessel wall.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 96 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Non-calcified active atherosclerosis plaque detection with 18F-NaF and 18F-FDG PET/CT dynamic imaging;Physical and Engineering Sciences in Medicine;2023-01-30

2. Exploring Atherosclerosis Imaging With FDG-PET in Motion;JACC: Cardiovascular Imaging;2022-12

3. Imaging High-Risk Atherothrombosis Using a Novel Fibrin-Binding Positron Emission Tomography Probe;Stroke;2022-02

4. Radionuclide-based imaging of the aortic wall;Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease;2022

5. Coupling of 18F-NaF and 18F-FDG PET/CT Dynamic Imaging for the Detection of Arterial Inflammation;2021 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC);2021-10-16

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3