Periprocedural Arterial Spin Labeling and Dynamic Susceptibility Contrast Perfusion in Detection of Cerebral Blood Flow in Patients With Acute Ischemic Syndrome

Author:

Nael Kambiz1,Meshksar Arash1,Liebeskind David S.1,Wang Danny J.J.1,Ellingson Benjamin M.1,Salamon Noriko1,Villablanca Juan Pablo1

Affiliation:

1. From the Department of Medical Imaging, University of Arizona, Tucson, AZ (K.N.); and Department of Radiological Sciences (A.M., B.E., N.S., P.J.V.) and Department of Neurology (D.S.L., D.J.J.W.), University of California, Los Angeles, CA.

Abstract

Background and Purpose— To compare the diagnostic performance of arterial spin-labeling (ASL) and dynamic susceptibility contrast (DSC) perfusion in detecting cerebral blood flow (CBF) changes before and after endovascular recanalization in acute ischemic syndrome. Methods— The inclusion criteria for this retrospective study were patients with acute ischemic syndrome who underwent endovascular recanalization and acquisition of both ASL and DSC before and after revascularization. ASL-CBF and multiparametric DSC maps were evaluated for image quality, location, and type of perfusion abnormality. Relative CBF (rCBF) was calculated in the infarction core and hypoperfused areas using coregistered ASL and DSC. Core and hypoperfused rCBF were used for paired pretreatment and posttreatment comparisons. Interobserver and intermodality agreement were evaluated by κ test, and t test was calculated for ASL and DSC rCBF values. Results— Twenty-five patients met our inclusion criteria. Five studies were rated nondiagnostic, resulting in 45 pairs of DSC–ASL available for comparison. ASL and DSC agreed on type and location of the perfusion abnormality in 71% and 80% of cases, respectively. The image quality of ASL was lower than DSC, resulting in interobserver variability for the type (κ=0.45) and location (κ=0.56) of perfusion abnormality. ASL was unable to show any type of perfusion abnormality in 11% of patients. In successfully recanalized patients, hyperperfusion (rCBF >1) was detected in 100% on DSC and 47% on ASL. Conclusions— ASL is less sensitive than DSC for detecting rCBF changes in patients with acute ischemic syndrome, particularly with respect to hyperperfusion after successful recanalization.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3