Maps of Time to Maximum and Time to Peak for Mismatch Definition in Clinical Stroke Studies Validated With Positron Emission Tomography

Author:

Zaro-Weber Olivier1,Moeller-Hartmann Walter1,Heiss Wolf-Dieter1,Sobesky Jan1

Affiliation:

1. From the Max Planck Institute for Neurological Research (O.Z.W., W.D.H.), Cologne, Germany; Departments of Neurology (O.Z.W.) and Diagnostic Radiology (W.M.H.), University of Cologne, Germany; Department of Neurology and Center for Stroke Research Berlin (O.Z.W., J.S.), Charité-Universitätsmedizin Berlin, Berlin, Germany.

Abstract

Background and Purpose— Perfusion-weighted imaging-derived maps of time-to-maximum (Tmax) are increasingly used to identify the tissue at risk in clinical stroke studies (eg, DEFUSE and EPITHET). Using quantitative positron emission tomography (PET), we evaluated Tmax to define the penumbral flow threshold in stroke patients and compared its performance to nondeconvolved time-to-peak (TTP) maps. Methods— Comparative perfusion-weighted imaging and quantitative 15O-water PET images of acute stroke patients were analyzed using cortical regions of interest. A receiver-operating characteristic curve analysis described the threshold independent performance of Tmax (area under the curve) and identified the best threshold (equal sensitivity and specificity threshold) to identify penumbral flow (<20 mL/100 g/min on PET cerebral blood flow). The results were compared with nondeconvolved TTP and other current perfusion-weighted imaging maps using the Mann–Whitney rank-sum test. Results— In 26 patients (time delay between MRI and PET, 65 minutes), the best threshold for penumbral flow was 5.5 seconds for Tmax (median; interquartile range, 3.9–6.6; sensitivity/specificity, 88%/89%). The area under the curve value was 0.95 (median; interquartile range, 0.93–0.97). Deconvolved Tmax did not perform significantly better than TTP ( P =0.34). Conclusion— Maps of Tmax detected penumbral flow but did not perform better than the easy-to-obtain maps of nondeconvolved TTP. Thus, “simple” TTP maps still remain suitable for clinical stroke studies if detailed postprocessing is not feasible.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3