Interrater Agreement for Final Infarct MRI Lesion Delineation

Author:

Neumann Anders B.1,Jonsdottir Kristjana Y.1,Mouridsen Kim1,Hjort Niels1,Gyldensted Carsten1,Bizzi Alberto1,Fiehler Jens1,Gasparotti Roberto1,Gillard Jonathan H.1,Hermier Marc1,Kucinski Thomas1,Larsson Elna-Marie1,Sørensen Leif1,Østergaard Leif1

Affiliation:

1. From the Center of Functionally Integrative Neuroscience (A.B.N., K.Y.J., K.M., N.H., C.G., L.Ø.), Aarhus University Hospitals, Aarhus, Denmark; Division of Neuroradiology (A.B.), Department of Experimental and Diagnostic Research, “C. Besta,” National Neurological Institute, Milan, Italy; Department of Neuroradiology (J.F.), University Medical Center Hamburg-Eppendorf, Hamburg, Germany; Dipartimento di Diagnostica per Immagini (R.G.), Neuroradiologia, Università degli Studi di Brescia, Brescia,...

Abstract

Background and Purpose— Lesion volume measured on follow-up magnetic resonance imaging (MRI) is commonly used as an outcome parameter in clinical stroke trials. However, few studies have evaluated the optimal sequence choice and the interrater reliability of this outcome measure. The objective of this study was to quantify the geometric interrater agreement for lesion delineation of chronic infarcts on T2-weighted and fluid-attenuated inverse recovery (FLAIR) MRI. Methods— In a retrospective study of 14 patients, lesions on 90-day follow-up FLAIR and T2 fast spin echo MRI were outlined by 9 independent, blinded, experienced neuroradiologists. Voxel-wise interrater agreement was measured as (1) the volume of the intersection of individual rater’s lesion outlines relative to the mean lesion volume (overlap ratio) and (2) the Hausdorff distance between the lesion markings. Results— Mean patient age was 64.4 years (range, 45 to 79). Lesion volumes on FLAIR were, on average, 2.5 mL greater than were T2 volumes (median; P <0.001). We found considerable differences between raters’ lesion markings, but interrater agreement was consistently better on FLAIR than on T2 images, as measured by a greater overlap ratio ( P <0.0001) and a smaller Hausdorff distance ( P <0.0001) on FLAIR than on T2. Conclusions— FLAIR should be used to quantify follow-up infarct size to minimize interrater variability. Our study suggests that imaging analysis performed by 1 or a few trained readers may be preferred. Future studies should address objective and preferably automated criteria for final lesion delineation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 35 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3