Multiphasic Computed Tomography Angiography Findings for Identifying Pseudo-Occlusion of the Internal Carotid Artery

Author:

Choi Jai Ho1,Jang Jinhee2ORCID,Koo Jaseong3,Ahn Kook-Jin2,Sam Shin Yong1,Kim Bum-soo2

Affiliation:

1. Departments of Neurosurgery (J.H.C., Y.S.S.), Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea.

2. Radiology (J.J., K.-J.A., B.-s.K.), Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea.

3. Neurology (J.K.), Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea.

Abstract

Background and Purpose: Differentiation between pseudo-occlusion and true occlusion of internal carotid artery (ICA) is important in treatment planning for acute ischemic stroke patients. We compared the findings of multiphasic computed tomography angiography between cervical ICA pseudo-occlusion and true occlusion at the cervical ICA in patients with anterior circulation acute ischemic stroke to determine their diagnostic value. Methods: Thirty patients with nonvisualization of the proximal ICA were included. Diagnosis of pseudo- or true occlusion of the ICA was made based on digital subtraction angiography. Diagnostic performances of multiphasic computed tomography angiography findings—(1) a flame-shaped stump and (2) delayed contrast filling at the cervical ICA— were evaluated and compared. The Fisher exact test, χ 2 test, or Wilcoxon rank-sum test and McNemar test were used in the data analysis. Results: Twelve patients had true proximal ICA occlusion and 18 had pseudo-occlusion. Delayed contrast filling at the cervical ICA on multiphasic computed tomography angiography was found in all patients with pseudo-occlusion of the ICA, while 1 case of true occlusion showed delayed contrast filling ( P <0.001). The presence of a flame-shaped stump was not significantly different between the pseudo- and true occlusion groups. The sensitivity of delayed contrast filling (0.94 [95% CI, 0.73–1]) was significantly higher than that of flame-shaped stump (0.75 [95% CI, 0.36–0.83]). Conclusions: We demonstrated that the delayed filling sign on multiphasic computed tomography angiography could be a useful and readily available finding for differentiating proximal ICA pseudo-occlusion from true occlusion.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialised Nursing,Cardiology and Cardiovascular Medicine,Clinical Neurology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3