Fast Automatic Detection of Large Vessel Occlusions on CT Angiography

Author:

Amukotuwa Shalini A.123,Straka Matus4,Dehkharghani Seena5,Bammer Roland367

Affiliation:

1. From the Diagnostic Imaging, Monash Medical Centre, Clayton, VIC, Australia (S.A.A.)

2. Department of Radiology, University Hospital Geelong, VIC, Australia (S.A.A.)

3. Department of Radiology and Medicine, Royal Melbourne Hospital, Parkville, VIC, Australia (S.A.A., R.B.)

4. Department of Neurology, Stanford Stroke Center, Stanford University, CA (M.S.)

5. Department of Radiology, NYU Langone Medical Center, NY (S.D.)

6. Florey Institute of Neurosciences, Parkville, VIC Australia (R.B.)

7. Department of Radiology, 3DQ Lab, Stanford University, CA (R.B).

Abstract

Background and Purpose— Accurate and rapid detection of anterior circulation large vessel occlusion (LVO) is of paramount importance in patients with acute stroke due to the potentially rapid infarction of at-risk tissue and the limited therapeutic window for endovascular clot retrieval. Hence, the optimal threshold of a new, fully automated software-based approach for LVO detection was determined, and its diagnostic performance evaluated in a large cohort study. Methods— For this retrospective study, data were pooled from: 2 stroke trials, DEFUSE 2 (n=62; 07/08–09/11) and DEFUSE 3 (n=213; 05/17–05/18); a cohort of endovascular clot retrieval candidates (n=82; August 2, 2014–August 30, 2015) and normals (n=111; June 6, 2017–January 28, 2019) from a single quaternary center; and code stroke patients (n=501; January 1, 2017–December 31, 2018) from a single regional hospital. All CTAs were assessed by the automated algorithm. Consensus reads by 2 neuroradiologists served as the reference standard. ROC analysis was used to assess diagnostic performance of the algorithm for detection of (1) anterior circulation LVOs involving the intracranial internal carotid artery or M1 segment middle cerebral artery (M1-MCA); (2) anterior circulation LVOs and proximal M2 segment MCA (M2-MCA) occlusions; and (3) individual segment occlusions. Results— CTAs from 926 patients (median age 70 years, interquartile range: 58-80; 422 females) were analyzed. Three hundred ninety-five patients had an anterior circulation LVO or M2-MCA occlusion (National Institutes of Health Stroke Scale 14 [median], interquartile range: 9–19). Sensitivity and specificity were 97% and 74%, respectively, for LVO detection, and 95% and 79%, respectively, when M2 occlusions were included. On analysis by occlusion site, sensitivities were 90% (M2-MCA), 97% (M1-MCA), and 97% (intracranial internal carotid artery) with corresponding area-under-the-ROC-curves of 0.874 (M2), 0.962 (M1), and 0.997 (intracranial internal carotid artery). Conclusions— Intracranial anterior circulation LVOs and proximal M2 occlusions can be rapidly and reliably detected by an automated detection tool, which may facilitate intra- and inter-instutional workflows and emergent imaging triage in the care of patients with stroke.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3