Quantitative Assessment of Core/Penumbra Mismatch in Acute Stroke

Author:

Schaefer Pamela W.1,Barak Elizabeth R.1,Kamalian Shahmir1,Gharai Leila Rezai1,Schwamm Lee1,Gonzalez Ramon Gilberto1,Lev Michael H.1

Affiliation:

1. From the Departments of Radiology (P.W.S., E.R.B., S.K., L.R.G., R.G.G., M.H.L.) and Neurology (L.S.), Massachusetts General Hospital, Harvard Medical School, Boston, Mass.

Abstract

Background and Purpose— Our purpose was to determine (1) the correlation between quantitative CT and MR measurements of infarct core, penumbra, and mismatch; and (2) whether the difference between these measurements would alter patient selection for stroke clinical trials. Methods— We studied 45 patients with acute middle cerebral artery stroke imaged a mean of 3.8 hours after onset (range, 0.48 to 8.35 hours) who underwent CT perfusion and MR diffusion (DWI)/perfusion imaging within 3 hours of each other. The DWI and MR-mean transit time (MTT) abnormalities were visually segmented using a semiautomated commercial analysis program. The CT-cerebral blood volume) and CT-MTT lesions were automatically segmented using a relative cerebral blood volume threshold of 0.56 and a relative MTT threshold of 1.50 on commercially available software. Percent mismatch was defined as [(MTT−DWI)/DWI volume]×100. Pearson correlation coefficients were calculated. Results— There were significant correlations for DWI versus CT-cerebral blood volume lesion volumes ( r 2 =0.88, P <0.001), for MR-MTT versus CT-MTT lesion volumes( r 2 =0.86, P <0.001), and for MR-MTT/DWI versus CT-MTT/CT-cerebral blood volume mismatch lesion volumes( r 2 =0.81, P <0.001). MR perfusion and CT perfusion agreed for determining: (1) infarct core < versus ≥100 mL in 41 of 45 (91.1%); (2) MTT lesion size < versus >2 cm diameter in 42 of 45 (93.3%); (3) mismatch < versus >20% in 41 of 45 (91.1%); and (4) inclusion versus exclusion from trial enrollment in 38 of 45 (84.4%) patients. Six of 7 disagreements were due to inadequate CT coverage. Conclusion— Advanced MR and CT perfusion imaging measurements of core/penumbra mismatch for patient selection in stroke trials are highly correlated when CT perfusion coverage is sufficient to include most of the ischemic region. Although MR is currently the preferred imaging method for determining core and penumbra, CT perfusion is comparable and potentially more available.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

Cited by 150 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3