CT Cerebral Blood Flow Maps Optimally Correlate With Admission Diffusion-Weighted Imaging in Acute Stroke but Thresholds Vary by Postprocessing Platform

Author:

Kamalian Shahmir1,Kamalian Shervin1,Maas Matthew B.1,Goldmacher Greg V.1,Payabvash Seyedmehdi1,Akbar Adnan1,Schaefer Pamela W.1,Furie Karen L.1,Gonzalez R. Gilberto1,Lev Michael H.1

Affiliation:

1. From the Departments of Radiology (Shahmir K., Shervin K., G.V.G., S.P., A.A., P.W.S., R.G.G., M.H.L.) and Neurology (M.B.M., K.L.F.), Massachusetts General Hospital, Harvard Medical School, Boston, MA.

Abstract

Background and Purpose— Admission infarct core lesion size is an important determinant of management and outcome in acute (<9 hours) stroke. Our purposes were to: (1) determine the optimal CT perfusion parameter to define infarct core using various postprocessing platforms; and (2) establish the degree of variability in threshold values between these different platforms. Methods— We evaluated 48 consecutive cases with vessel occlusion and admission CT perfusion and diffusion-weighted imaging within 3 hours of each other. CT perfusion was acquired with a “second-generation” 66-second biphasic cine protocol and postprocessed using “standard” (from 2 vendors, “A-std” and “B-std”) and “delay-corrected” (from 1 vendor, “A-dc”) commercial software. Receiver operating characteristic curve analysis was performed comparing each CT perfusion parameter—both absolute and normalized to the contralateral uninvolved hemisphere—between infarcted and noninfarcted regions as defined by coregistered diffusion-weighted imaging. Results— Cerebral blood flow had the highest accuracy (receiver operating characteristic area under the curve) for all 3 platforms ( P <0.01). The maximal areas under the curve for each parameter were: absolute cerebral blood flow 0.88, cerebral blood volume 0.81, and mean transit time 0.82 and relative Cerebral blood flow 0.88, cerebral blood volume 0.83, and mean transit time 0.82. Optimal receiver operating characteristic operating point thresholds varied significantly between different platforms (Friedman test, P <0.01). Conclusions— Admission absolute and normalized “second-generation” cine acquired CT cerebral blood flow lesion volumes correlate more closely with diffusion-weighted imaging-defined infarct core than do those of CT cerebral blood volume or mean transit time. Although limited availability of diffusion-weighted imaging for some patients creates impetus to develop alternative methods of estimating core, the marked variability in quantification among different postprocessing software limits generalizability of parameter map thresholds between platforms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Cardiology and Cardiovascular Medicine,Neurology (clinical)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3