Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.

Author:

Hook B G1,Callans D J1,Kleiman R B1,Flores B T1,Marchlinski F E1

Affiliation:

1. Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia 19104.

Abstract

BACKGROUND This report describes the value of stored ventricular electrogram analysis in the diagnosis and management of patients experiencing minimal or no symptoms before implantable cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS The study population included 48 patients who received the Cadence Tiered Therapy Defibrillator System, an investigational third-generation ICD with ventricular electrogram storage capabilities. Criteria for arrhythmia diagnosis were based on analysis of the electrogram rate, RR interval variability, and morphology. Twenty-nine of the 48 patients (60%) experienced at least one episode of antitachycardia pacing or shock (one shock or more in 25 of 29 patients) that was preceded by minimal or no symptoms during a mean follow-up of 15.1 +/- 7.8 months. There were 194 tachycardia episodes registered by the device, including 101 for which ventricular electrograms were stored and available for analysis. Of the 101 stored electrograms, 74 were classified as ventricular tachycardia (VT), 24 as non-VT rhythms (atrial fibrillation, 13; supraventricular tachycardia, six; rate-sensing lead disruption, four; T wave oversensing, one), and only three as indeterminate rhythms. Based on the electrogram analysis, changes in tachycardia detection criteria and/or antiarrhythmic drug regimens were implemented and were associated with a reduction in the number of device responses for non-VT rhythms from 24 during the initial study period to three during 11.0 +/- 7.2 months of additional follow-up. CONCLUSIONS ICD responses in the absence of symptoms are relatively common in third-generation devices with antitachycardia pacing capabilities. Despite potential limitations such as the effect of bundle branch block on the electrogram morphology during supraventricular tachycardia, the availability of electrogram storage capabilities allowed a presumptive diagnosis of the events precipitating asymptomatic device responses. Device reprogramming based on analysis of stored electrograms was associated with a dramatic reduction in the incidence of ICD responses for non-VT rhythms.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 111 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3