Catheter ablation of the atrioventricular junction with radiofrequency energy.

Author:

Langberg J J1,Chin M C1,Rosenqvist M1,Cockrell J1,Dullet N1,Van Hare G1,Griffin J C1,Scheinman M M1

Affiliation:

1. Department of Medicine, University of California, San Francisco.

Abstract

Catheter ablation of the atrioventricular junction using direct-current defibrillator discharges requires general anesthesia and may have serious side effects. Sixteen patients with drug-refractory supraventricular tachycardia underwent catheter ablation of the atrioventricular junction using radiofrequency energy. A standard 7F quadripolar electrode catheter was positioned to record the largest unipolar His potential (580 +/- 640 microV) from the distal electrode. An electrocoagulator (Microvasive Bicap 4005) supplied continuous, unmodulated energy at 550 kHz. One to 14 applications of radiofrequency current were delivered between the distal electrode and a large-diameter chest wall electrode. Transient, mild chest discomfort was reported by seven of 16 patients. None had significant arrhythmias or blood pressure changes during radiofrequency ablation. Complete atrioventricular block was produced in nine of 16 patients and high-grade second-degree atrioventricular block was produced in one patient with radiofrequency current. Attenuated His bundle electrograms could still be recorded in the remaining six patients, four of whom underwent successful atrioventricular junctional ablation using direct-current shock during the same session. Atrioventricular block persisted in all 10 patients successfully treated with radiofrequency ablation during a mean follow-up of 4.2 months. Compared with a group of historic control subjects treated with direct-current shock ablation, the 10 patients successfully treated with radiofrequency current had significantly less creatine kinase-MB isoenzyme release (5.7 +/- 5.1 vs. 22 +/- 13 IU, p = 0.006). A junctional escape rhythm was present in all patients after radiofrequency-induced atrioventricular block. In contrast, three of 10 control patients had an idioventricular escape after direct current shock ablation, and four patients had no escape rhythm at all.(ABSTRACT TRUNCATED AT 250 WORDS)

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

Cited by 230 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3