Effect of duration of ventricular fibrillation on defibrillation efficacy in humans.

Author:

Winkle R A1,Mead R H1,Ruder M A1,Smith N A1,Buch W S1,Gaudiani V A1

Affiliation:

1. Cardiovascular Section, Sequoia Hospital, Redwood City, California.

Abstract

The currently available automatic implantable cardioverter-defibrillator has proven highly successful for termination of ventricular tachycardia and fibrillation. Newer devices, however, permit lower energy shocks to be delivered initially and longer episodes of arrhythmia to occur before shocks are delivered. These changes may result in longer durations of arrhythmia before successful termination. Little is known about the effects of the duration of ventricular fibrillation on the efficacy of defibrillating shocks. In this study, we examined the efficacy of defibrillating shocks in 22 patients undergoing automatic implantable cardioverter-defibrillator implantation or generator change. Defibrillating shocks ranging from 300 to 600 V (5.9-24.2 J) were delivered in matched pairs after 5 and 15 seconds of ventricular fibrillation. For the 300-V shocks (5.9 J), defibrillation was accomplished in 82% of patients when the shocks were given after 5 seconds of ventricular fibrillation and in only 45% of patients when the shocks were delivered after 15 seconds (p less than 0.01). At higher energies, there was no difference in the efficacy of defibrillation shocks delivered after 5 compared with 15 seconds of ventricular fibrillation. The postshock aortic, systolic, and diastolic blood pressures were significantly lower when the shocks were given after 15 seconds of ventricular fibrillation than after only 5 seconds. We conclude that the duration of ventricular fibrillation affects defibrillation efficacy especially at energies that are relatively low compared with maximal device outputs and that longer episodes of ventricular fibrillation cause more postshock hemodynamic depression. These observations have implications for defibrillation threshold testing at the time of device implantation and for the design and programming of future automatic implantable antitachycardia devices.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Physiology (medical),Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3